Biacore is a life science products company, based in Sweden. In June 2006 GE Healthcare acquired Biacore for $390 million.[1]
Biacore specializes in measuring protein-protein interaction and binding affinity. The technology is based on surface plasmon resonance (SPR), an optical phenomenon that enables detection of unlabeled interactants in real time. The SPR-based biosensors can be used in determination of active concentration as well as characterization of molecular interactions in terms of both affinity and chemical kinetics.
History
Biacore was founded in 1984 under the name of Pharmacia Biosensor AB, by researchers from Pharmacia, Linköping Institute of Technology and the Swedish National Defence Research Institute (FOA, now renamed the Swedish Defence Research Agency or FOI). The first Biacore SPR instrument was commercially released in 1990. In 1996 the company changed its name to Biacore AB Corporation.[2]
Technology
Biacore's competition includes switchSENSE technology from Dynamic Biosensors,[3] Attana AB[4] (a Stockholm based biotechnology firm), BIOSUPLAR[5] (a German nanoscience company), Bio-Rad Laboratories' ProteOn XPR36 Protein Interaction Array System (Hercules, California), Sapidyne's KinExA[6] platform (Boise, ID), ForteBio's[7] Octet QK,QK384,QKe,RED,RED384 instruments (Menlo Park, CA), SensiQ (Oklahoma City, OK),[8] BioNavis'[9] MP-SPR Navi 200 OTSO, 210A VASA, 220A NAALI and a 4-channel 420A ILVES (Tampere, Finland), Reichert's dual-channel SPR systems (Depew, NY), IBIS Technologies' MX96 multiplex SPR imaging system (Enschede, Netherlands), BiOptix' 404pi system (Boulder, CO), and Plexera's PlexArray HT (Woodinville, WA).[10]
A simple interaction experiment involves immobilizing one molecule of a binding pair on the sensor chip surface ("ligand", in Biacore parlance) and injecting a series of concentrations of its partner ("analyte") across the surface. Changes in the index of refraction at the surface where the binding interaction occurs are detected by the hardware and recorded as RU (resonance units) in the control software. Curves are generated from the RU trace and are evaluated by fitting algorithms which compare the raw data to well-defined binding models. These fits allow determination of a variety of thermodynamic constants, including the apparent affinity of the binding interaction. SPR is one of many methods for protein-protein and protein-ligand interaction assessment, see Methods to investigate protein–protein interactions.
External links
References
- ↑ http://www.biacore.com/lifesciences/index.html
- ↑ "History". biacore.com. Retrieved 7 Jan 2015.
- ↑ http://www.dynamic-biosensors.com/
- ↑ http://www.attana.com/
- ↑ http://www.biosuplar.com/
- ↑ http://www.sapidyne.com/
- ↑ http://www.fortebio.com
- ↑ http://www.discoversensiq.com
- ↑ http://www.bionavis.com
- ↑ http://www.plexera.com