Central differencing scheme

Figure 1.Comparison of different schemes

In applied mathematics, the central differencing scheme is a finite difference method. The finite difference method optimizes the approximation for the differential operator in the central node of the considered patch and provides the numerical solution for differential equation.[1] The central differencing scheme is one of the schemes to solve the integrated convection-diffusion equation and in a way to solution, calculation of transported property Φ at the e and w faces is required and hence central differencing scheme provides a method to calculate these transported property. The advantages of this method are that it is easy to understand and to implement, at least for simple material relations. The right hand side of the convection-diffusion equation which basically highlights the diffusion terms can be represented using central difference approximation. Thus, in order to simplify the solution and analysis, linear interpolation can be used logically to compute the cell face values for the left hand side of this equation which is nothing but the convective terms. Therefore cell face values of property for a uniform grid can be written as [2]

\Phi_e =(\Phi_P + \Phi_E)/2
\Phi_w =(\Phi_W + \Phi_P)/2

Steady-state convection diffusion equation

The convection–diffusion equation is a collective representation of both diffusion and convection equations and describes or explains every physical phenomenon involving the two processes: convection and diffusion in transferring of particles, energy or other physical quantities inside a physical system. The convection-diffusion is as follows:[3]

\operatorname{div}(\rho u\varphi)=\operatorname{div}(\Gamma\nabla\varphi)+S_\varphi; \,

here Г is diffusion coefficient and Φ is the property

Formulation of steady-state convection diffusion equation

Formal integration of steady-state convection–diffusion equation over a control volume gives

\int\limits_A \, n\cdot(\rho u\varphi)\,dA = \int\limits_A \,n \cdot (\Gamma\nabla\varphi)\,dA+\int\limits_{CV}\,S_\varphi \,dV → Equation 1.

This equation represents flux balance in a control volume. The left hand side gives the net convective flux and the right hand side contains the net diffusive flux and the generation or destruction of the property within the control volume.

In the absence of source term equation one becomes

{d \over dx}(\rho u\varphi) = {d \over dx}\left( {d\varphi \over dx}\right) → Equation 2.

Continuity equation:

{d \over dx}(\rho u)=0 → Equation 3.
Figure 2. Interpolation method

Assuming a control volume and integrating equation 2 over control volume gives:

(\rho u\varphi A)_e  - (\rho u\varphi A)_w = (\Gamma A d\varphi /dx)_e -   (\Gamma A d\varphi /dx)_wIntegrated convection–diffusion equation

Integration of equation 3 yields:

(\rho uA)_e - (\rho uA)_w = 0Integrated continuity equation

It is convenient to define two variables to represent the convective mass flux per unit area and diffusion conductance at cell faces which is as follows :

F = \rho u
D = \Gamma / \delta x

Assuming A_e = A_w , we can write integrated convection–diffusion equation as:

F_e \varphi_e - F_w \varphi_w = D_e( \varphi_E - \varphi_P ) - D_w(\varphi_P - \varphi_W)

And integrated continuity equation as:

F_e - F_w = 0

In central differencing scheme we try linear interpolation to compute cell face values for convection terms.

For a uniform grid we can write cell face values of property Φ as

\varphi_e = (\varphi_E + \varphi_P)/2, \quad \varphi_w = (\varphi_P + \varphi_W)/2

On substituting this into integrated convection – diffusion equation we obtain,

F_e\frac{\varphi_E + \varphi_P}2 - F_w\frac{\varphi_W + \varphi_P}2 = D_e(\varphi_E - \varphi_P) -  D_w(\varphi_P - \varphi_W)

And on rearranging,

\left[\left(D_w + \frac{F_w}2\right) + \left(D_e - \frac{F_e}2\right) + (F_e - F_w)\right]\varphi_P = \left(D_w + \frac{F_w}2 \right)\varphi_W + \left(D_e - \frac{F_e}2 \right)\varphi_E

a_P \varphi_P =  a_W \varphi_W + a_E\varphi_E

Different aspects of central differencing scheme

Conservativeness

Conservation is ensured in central differencing scheme since overall flux balance is obtained by summing the net flux through each control volume taking into account the boundary fluxes for the control volumes around nodes 1 and 4.

Figure 3.Typical illustration

Boundary flux for control volume around node 1 and 4


\begin{align}
& \left[\frac{\Gamma_{e_1} (\varphi_2 - \varphi_1)}{ \delta x} - q_A\right] + \left[ \frac {\Gamma_{e_2} (\varphi_3 - \varphi_2)}{ \delta x} - \frac{ \Gamma_{w_2} (\varphi_2 - \varphi_1)}{ \delta x}\right] \\[10pt]
+ {} & \left[ \frac{ \Gamma_{e_3} (\varphi_4 - \varphi_3)}{\delta x} - \frac{\Gamma_{w_3} (\varphi_3 - \varphi_2)}{\delta x}\right] + \left[q_B -  \frac{\Gamma_{w_4} (\varphi_4 - \varphi_3)}{\delta x}\right] = q_B - q_A
\end{align}

because \Gamma_{e_1} = \Gamma_{w_2} , \Gamma_{e_2} = \Gamma_{w_3} , \Gamma_{e_3} = \Gamma_{w_4}

Boundedness

Central differencing scheme satisfies first condition of Boundedness.

Since F_e - F_w = 0 from continuity equation, therefore; a_P \varphi_P =  a_W \varphi_W + a_E\varphi_E

Another essential requirement for Boundedness is that all coefficients of the discretised equations should have the same sign (usually all positive). But this is only satisfied when (peclet number) F_e/D_e < 2 because for a unidirectional flow(F_e >0, F_w > 0) a_E = (D_e - F_e/2) is always positive if D_e > F_e/2

Transportiveness

It requires that transportiveness changes according to magnitude of peclet number i.e. when pe is zero \varphi is spread in all directions equally and as Pe increases (convection > diffusion) \varphi at a point largely depends on upstream value and less on downstream value. But central differencing scheme does not possess Transportiveness at higher pe since Φ at a point is average of neighbouring nodes for all Pe.

Accuracy

The Taylor series truncation error of the central differencing scheme is second order. Central differencing scheme will be accurate only if Pe < 2. Owing to this limitation central differencing is not a suitable discretisation practice for general purpose flow calculations.

Applications of central differencing scheme

Advantages

Disadvantages

See also

References

  1. Computational fluid dynamics –T CHUNG, ISBN 0-521-59416-2
  2. An introduction to computational fluid dynamics by HK VERSTEEG and W.MALALASEKERA, ISBN 0-582-21884-5
  3. An introduction to computational fluid dynamics by HK VERSTEEG and W.MALALASEKERA, ISBN 0-582-21884-5
  4. http://link.springer.com/article/10.1007/s002110050345
  5. http://link.springer.com/article/10.1007/s002110050345
  6. http://www.bakker.org/dartmouth06/engs150/05-solv.ppt

Further reading

External links

This article is issued from Wikipedia - version of the Friday, May 29, 2015. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.