Coagulase

(TEM cryomicroscopy technique) - S. aureus forms a fibrin capsule that protects it from the immune system of cattle

Coagulase is a protein enzyme produced by several microorganisms that enables the conversion of fibrinogen to fibrin. In the laboratory, it is used to distinguish between different types of Staphylococcus isolates. Importantly, S. aureus is generally coagulase-positive, meaning that coagulase negativity usually excludes S. aureus. However it is now known that not all S. aureus are coagulase-positive.[1][2]

It is also produced by Yersinia pestis.[3]

Coagulase reacts with prothrombin in the blood. The resulting complex is called staphylothrombin, which enables the enzyme protease to convert fibrinogen, a plasma protein produced by the liver, to fibrin. This results in clotting of the blood. Coagulase is tightly bound to the surface of the bacterium S. aureus and can coat its surface with fibrin upon contact with blood. The fibrin clot may protect the bacterium from phagocytosis and isolate it from other defenses of the host.[4] It has been proposed that fibrin-coated staphylococci resist phagocytosis, making the bacteria more virulent. Bound coagulase is part of the larger family of MSCRAMM.

Coagulase test

The coagulase test has traditionally been used to differentiate Staphylococcus aureus from coagulase-negative staphylococci. S.aureus produces two forms of coagulase (i.e., bound coagulase and free coagulase). Bound coagulase, otherwise known as "clumping factor", can be detected by carrying out a slide coagulase test, and free coagulase can be detected using a tube coagulase test.

Slide test

A slide coagulase test is run with a negative control to rule out autoagglutination. Two drops of saline are put onto the slide labeled with sample number, Test (T) and control (C). The two saline drops are emulsified with the test organism using a wire loop, straight wire, or wooden stick. A drop of plasma (rabbit plasma anticoagulated with EDTA is recommended)[5] is placed on the inoculated saline drop corresponding to test, and mixed well, then the slide is rocked gently for about 10 seconds.

If the slide coagulase test is negative, a tube test should follow as a confirmation. Clumping in both drops is an indication of autoagglutination, so a tube test should be carried out. Tube test is not performed each institutions but most of the result depends on blood cultures from lab.

Tube test

A fibrin clot formed in a test tube by the coagulase reaction

The tube test uses rabbit plasma that has been inoculated with a staphylococcal colony (i.e., Gram-positive cocci which are catalase positive). The tube is then incubated at 37 °C for 1.5 hours. If negative, then incubation is continued up to 18 hours.

References

  1. Ryan KJ, Ray CG (editors) (2004). Sherris Medical Microbiology (4th ed.). McGraw Hill. ISBN 0-8385-8529-9.
  2. PreTest, Surgery, 12th ed., p.88
  3. "coagulase" at Dorland's Medical Dictionary
  4. Tortora, Gerard J.; Funke, Berdell R.; Case, Christine L. (2013). Microbiology: An Introduction (11 ed.). Glenview, IL: Pearson Education Inc. p. 434. ISBN 978-0-321-73360-3.
  5. A.Forbes, Betty; Daniel F.Sahm; Alice S.Weissfeld. BAILEY& SCOTT'S Diagnostic Microbiology (Tenth ed.). Don Ladig. pp. 430–431. ISBN 0-8151-2535-6.
  6. "coagulase test" at Dorland's Medical Dictionary

External links

This article is issued from Wikipedia - version of the Friday, March 11, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.