Septic drain field

Septic tank and septic drain field.

Septic drain fields, also called leach fields or leach drains are used to remove contaminants and impurities from the liquid that emerges from the septic tank. A septic tank, the septic drain field, and the associated piping compose a complete septic system. The septic drain field is effective for disposal of organic materials readily catabolized by a microbial ecosystem. The drain field typically consists of an arrangement of trenches containing perforated pipes and porous material (often gravel) covered by a layer of soil to prevent animals and surface runoff from reaching the wastewater distributed within those trenches.[1] Primary design considerations are hydraulic for the volume of wastewater requiring disposal and catabolic for the long-term biochemical oxygen demand of that wastewater.

Hydraulic design

Cross-section of weeping tile and leach field

Many health departments require a percolation test ("perc" test) to establish suitability of drain field soil to receive septic tank effluent. An engineer or licensed designer may be required to work with the local governing agency to design a system that conforms to these criteria.

Wastewater from toilets is assumed to contain bacteria and viruses capable of causing disease. Disinfection methods used prior to surface disposal of municipal sewage cannot be used with septic tanks because disinfection would prevent wastewater treatment by killing the septic tank and soil ecosystems catabolizing the putrescible contents of the wastewater. A properly functioning drain field holds and deactivates pathogens before they leave the drain field soil.

The goal of percolation testing is to ensure the soil is permeable enough for septic tank effluent to percolate away from the drain field, but fine grained enough to filter out pathogenic bacteria and viruses before they travel far enough to reach a water well or surface water supply. Coarse soils sand and gravel can transmit wastewater away from the drain field before pathogens are destroyed. Silt and clay effectively filter out pathogens but allow very limited wastewater flow rates.[2] Percolation tests measure the rate at which clean water disperses through a disposal trench into the soil. Several factors may reduce observed percolation rates when the drain field receives anoxic septic tank effluent:[3]

Dosing schedules or resting periods

A drain field may be designed to offer several separate disposal areas for effluent from a single septic tank. One area may be "rested" while effluent is routed to a different area. The nematode community in the resting drain field continues feeding on the accumulated biofilm and fats when the anaerobic septic tank effluent is no longer available. This natural cleansing process may improve hydraulic capacity of the field by increasing available interstitial area of the soil as accumulated organic material is oxidized. The percolation rate after resting may approach, but is unlikely to match, the original clean water percolation rate of the site.

Catabolic design

Just as the septic tank is sized to support a community of anaerobic organisms capable of liquifying anticipated amounts of putresible materials in wastewater, the drain field should be sized to support a community of aerobic soil microorganisms capable of decomposing the anaerobic septic tank's effluent into aerobic water. Hydrogen sulfide odors or iron bacteria may be observed in nearby wells or surface waters when effluent has not been completely oxidized prior to reaching those areas.[6] The biofilm on the walls of the drain field trenches will use atmospheric oxygen in the trenches to catabolize organic compounds in septic tank effluent. Groundwater flow is laminar in the aquifer soils surrounding the drain field.[7] Septic tank effluent with soluble organic compounds passing through the biofilm forms a mounded lens atop groundwater underlying the drain field. Molecular diffusion controls mixing of soluble organic compounds into groundwater and transport of oxygen from underlying groundwater or the capillary fringe of the groundwater surface to micro-organisms capable of catabolizing dissolved organic compounds remaining in the effluent plume.[8]

Biofilter

When a septic tank is used in combination with a biofilter, the height and catabolic area of the drain field may be reduced. This technology may allow higher density residential construction, minimal site disturbance, more usable land for trees, swimming pools, or gardens. With adequate routine maintenance it may reduce the chances of the drain field plugging up. The biofilter will not reduce the volume of liquid that must percolate into soil, but it may reduce the oxygen demand of organic materials in that liquid.

Inappropriate wastes

Septic drain field exposed by flood damage.

Septic tank and drain field microorganisms have very limited capability for catabolizing petroleum products and chlorinated solvents, and cannot remove dissolved metals; although some may sorb onto septic tank sludge or drain field soils, and concentrations may be diluted by other groundwater in the vicinity of the drain field. Cleaning formulations may reduce drain field efficiency. Laundry bleach may slow or stop microbial activity in the drain field, and sanitizing or deodorizing chemicals may have similar effects. Detergents, solvents and drain cleaners may transport emulsified, saponified or dissolved fats into the drain field before they can be catabolized to short-chain organic acids in the septic tank scum layer.[6]

See also

Wikimedia Commons has media related to Self-contained drainage system.

Notes

  1. Steel, E.W. & McGhee,Terence J. "Water Supply and Sewerage"McGraw-Hill Book Company (1979) ISBN 0-07-060929-2 pp.576-577
  2. Alth, Max & Charlotte "Constructing and Maintaining your Well & Septic System" Tab Books (1984) ISBN 0-8306-0654-8 pp.166-167
  3. Alth, Max & Charlotte "Constructing and Maintaining your Well & Septic System" Tab Books (1984) ISBN 0-8306-0654-8 p.217
  4. Alth, Max & Charlotte "Constructing and Maintaining your Well & Septic System" Tab Books (1984) ISBN 0-8306-0654-8 pp.164-165&219
  5. Alth, Max & Charlotte "Constructing and Maintaining your Well & Septic System" Tab Books (1984) ISBN 0-8306-0654-8 p.219
  6. 1 2 3 4 Hammer, Mark J. "Water and Waste-water Technology" John Wiley & Sons (1975) ISBN 0-471-34726-4 pp.407-408
  7. Linsley, Ray K. & Franzini, Joseph B. "Water-Resources Engineering (2nd Ed.)" McGraw-Hill Book Company (1972) ISBN 978-0-07-037959-6, p.88
  8. Perry, Robert H., Chilton, Cecil H. & Kirkpatrick, Sidney D. "Chemical Engineers' Handbook (4th Ed.)" McGraw-Hill Book Company (1963) p.14-13
This article is issued from Wikipedia - version of the Monday, March 14, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.