External Active Thermal Control System

ISS External Active Thermal Control System (EATCS) diagram
Early Ammonia Servicer
DDCU cold plate design

The International Space Station (ISS) External Active Thermal Control System (EATCS)[1] maintains an equilibrium when the ISS environment or heat loads exceed the capabilities of the Passive Thermal Control System (PTCS). Note Elements of the PTCS are external surface materials, insulation such as MLI, or Heat Pipes. The EATCS provides heat rejection capabilities for all the US pressurised modules, including the JEM and COF as well as the main power distribution electronics of the S0, S1 and P1 Trusses. The EATCS consists of two independent Loops (Loop A & Loop B), they both use mechanically pumped Ammonia in fluid state, in closed-loop circuits. The EATCS is capable of rejecting up to 70 kW, and provides a substantial upgrade in heat rejection capacity from the 14 kW capability of the Early External Active Thermal Control System (EEATCS) via the Early Ammonia Servicer (EAS), which was launched on STS-105 and installed onto the P6 Truss.[2]

There are two independent Loops (Loop A & Loop B) that combined make up the EATCS. The EATCS Loops perform three primary functions:

EATCS schematic overview
EATCS components on the S1/P1 Trusses
TCS System of the ISS