Environmental control system (aircraft)
The environmental control system (ECS) of an aircraft provides air supply, thermal control and cabin pressurization for the crew and passengers. Avionics cooling, smoke detection, and fire suppression are also commonly considered part of an aircraft's environmental control system.
Overview
The systems described below are specific to current production Boeing airliners, although the details are essentially identical for passenger jets from Airbus and other companies. An exception was Concorde which had a supplementary air supply system fitted due to the higher altitudes at which it flew, and also the slightly higher cabin pressure it employed.
Air supply
On jetliners, air is supplied to the ECS by being bled from a compressor stage of each gas turbine engine, upstream of the combustor. The temperature and pressure of this bleed air varies according to which compressor stage is used, and the power setting of the engine. A manifold pressure regulating shut-off valve (MPRSOV) restricts the flow as necessary to maintain the desired pressure for downstream systems.
A certain minimum supply pressure is needed to drive the air through the system, but it is desired to use as low a supply pressure as possible, because the energy the engine uses to compress the bleed air is not available for propulsion, and fuel consumption suffers. For this reason, air is commonly drawn from one of two (or in some cases such as the Boeing 777, three) bleed ports at different compressor stage locations. When the engine is at low pressure (low thrust or high altitude), the air is drawn from the highest pressure bleed port. As pressure is increased (more thrust or lower altitude) and reaches a predetermined crossover point, the high pressure shut-off valve (HPSOV) closes and air is selected from a lower pressure port to minimize the fuel performance loss. The reverse happens as engine pressure decreases.
To achieve the desired temperature, the bleed-air is passed through a heat exchanger called a pre-cooler. Air bled from the engine fan is blown across the pre-cooler, located in the engine strut, and absorbes excess heat from the service bleed air. A fan air modulating valve (FAMV) varies the cooling airflow to control the final air temperature of the service bleed air.
Cold air unit
At the heart of the "cold air unit" (CAU) is the "Air Cycle Machine" (ACM) cooling device. Some aircraft, including early 707 jetliners, used vapor-compression refrigeration like that used in home air conditioners.
An ACM uses no Freon: the air itself is the refrigerant. The ACM is preferred over vapor cycle devices because of reduced weight and maintenance requirements.
On most jetliners, the A/C packs are located in the "wing to body fairing" between the two wings beneath the fuselage. On some jetliners (Douglas Aircraft DC-9 Series) the A/C packs are located in the tail. The A/C packs on the McDonnell Douglas DC-10/MD-11 and Lockheed L-1011 are located in the front of the aircraft beneath the flight deck. Nearly all jetliners have two packs, although larger aircraft such as the Boeing 747, Lockheed L-1011, and McDonnell-Douglas DC-10/MD-11 have three.
The quantity of bleed air flowing to the A/C pack is regulated by the "flow control valve" (FCV). One FCV is installed for each pack. A normally closed "isolation valve" prevents air from the left bleed system from reaching the right pack (and vice versa), although this valve may be opened in the event of loss of one bleed system.
Downstream of the FCV is the cold air unit (CAU), also referred to as the refrigeration unit. There are many various types of CAUs; however, they all use typical fundamentals. The bleed air enters the primary "ram air heat exchanger", where it is cooled by either ram air, expansion or a combination of both. The cold air then enters the compressor, where it is re-pressurized, which reheats the air. A pass through the secondary "ram air heat exchanger" cools the air while maintaining the high pressure. The air then passes through a turbine which expands the air to further reduce heat. Similar in operation to a turbo-charger unit, the compressor and turbine are on a single shaft. The energy extracted from the air passing through the turbine is used to power the compressor. The air flow then is directed to the Re-heater before it passes to the condenser to be ready for water extraction by water extractor
The air is then sent through a water separator, where the air is forced to spiral along its length and centrifugal forces cause the moisture to be flung through a sieve and toward the outer walls where it is channeled toward a drain and sent overboard. Then, the air usually will pass through a water separator coalescer or the sock. The sock retains the dirt and oil from the engine bleed air to keep the cabin air cleaner. This water removal process prevents ice from forming and clogging the system, and keeps the cockpit and cabin from fogging on ground operation and low altitudes.
For a sub-zero bootstrap CAU, the moisture is extracted before it reaches the turbine so that sub-zero temperatures may be reached.
The temperature of the pack outlet air is controlled by the adjusting flow through the "ram air system" (below), and modulating a "temperature control valve" (TCV) which bypasses a portion of the hot bleed air around the ACM and mixes it with the cold air downstream of the ACM turbine.
Ram air system
The "ram air inlet" is a small scoop, generally located on the "wing to body fairing." Nearly all jetliners use a modulating door on the ram air inlet to control the amount of cooling airflow through the primary and secondary ram air heat exchangers.
To increase ram air recovery, nearly all jetliners use modulating vanes on the ram air exhaust. A "ram air fan" within the ram system provides ram air flow across the heat exchangers when the aircraft is on the ground. Nearly all modern fixed-wing aircraft use a fan on a common shaft with the ACM, powered by the ACM turbine.
Air distribution
The A/C pack exhaust air is ducted into the pressurized fuselage, where it is mixed with filtered air from the recirculation fans, and fed into the "mix manifold". On nearly all modern jetliners, the airflow is approximately 50% "outside air" and 50% "filtered air."
Modern jetliners use "high efficiency particulate arresting" HEPA filters, which trap more than 99% of all bacteria and clustered viruses.
Air from the "mix manifold" is directed to overhead distribution nozzles [1] in the various "zones" of the aircraft. Temperature in each zone may be adjusted by adding small amounts of "trim air", which is low-pressure, high-temperature air tapped off the A/C pack upstream of the TCV. Air is also supplied to individual gaspers: small, circular vents above each passenger seat that can be adjusted by passengers for their personal comfort. A revolving control on the vent can be turned to adjust ventilation between no air output at all and a fairly substantial breeze.
Gaspers usually receive their air from the air conditioning packs aboard the aircraft, which in turn receive compressed, clean air from the compressor stages of the aircraft's jet engines or when on the ground from the auxiliary power unit (APU) or a ground source. A master control for gaspers is located in the cockpit, and gaspers may be temporarily turned off during certain phases of flight, when the load on the engines from bleed-air demands must be minimized (e.g. take-off and climb).
Pressurization
Airflow into the fuselage is approximately constant, and pressure is maintained by varying the opening of the "out-flow valve" (OFV). Most modern jetliners have a single OFV located near the bottom aft end of the fuselage, although some larger aircraft like the 747 and 777 have two.
In the event the OFV should fail closed, at least two positive pressure relief valves (PPRV) and at least one negative pressure relief valve (NPRV) are provided to protect the fuselage from over- and under- pressurization.
Aircraft cabin pressure is commonly pressurized to a "cabin altitude" of 8000 feet or less. That means that the pressure is 10.9 pounds per square inch (75 kPa), which is the ambient pressure at 8,000 feet (2,400 m). Note that a lower cabin altitude is a higher pressure. The cabin pressure is controlled by a "cabin pressure schedule", which associates each aircraft altitude with a cabin altitude. The new airliners such as the Airbus A380 and Boeing 787 will have lower maximum cabin altitudes which help in passenger fatigue reduction during flights.
The atmosphere at typical jetliner cruising altitudes is generally very dry and cold; the outside air pumped into the cabin on a long flight has the potential to cause condensation which might in turn cause corrosion or electrical faults, and is thus eliminated. Consequently, when humid air at lower altitudes is encountered and drawn in, the ECS dries it through the warming and cooling cycle and the water separator mentioned above, so that even with high external relative humidity, inside the cabin it will usually be not much higher than 10% relative humidity.
Although low cabin humidity has health benefits of preventing the growth of fungus and bacteria, the low humidity causes drying of the skin, eyes and mucosal membranes and contributes to dehydration, leading to fatigue, discomfort and health issues. In one study the majority of flight attendants reported discomfort and health issues from low humidity.[2] In a statement to US Congress in 2003 a member of the Committee on Air Quality in Passenger Cabins of Commercial Aircraft said "low relative humidity might cause some temporary discomfort (e.g., drying eyes, nasal passages, and skin), but other possible short- or long-term effects have not been established".[3]
A cabin humidity control system may be added to the ECS of some aircraft to keep relative humidity from extremely low levels, consistent with the need to prevent condensation.[4] Furthermore, the Boeing 787 and Airbus 350, by using more corrosion-resistant composites in their construction, can operate with a cabin relative humidity of 16% on long flights.
Health concerns
The bleed air comes from the engines but is "bled" from the engine upstream of the combustor. Air cannot flow backwards through the engine except during a compressor stall (essentially a jet engine backfire), thus the bleed air should be free of combustion contaminants from the normal running of the aircraft's own engines.
However, on occasions carbon seals can leak oil (containing potentially hazardous chemicals) into the bleed air, in what is known in the industry as a "fume event".[5] This is generally dealt with quickly since failed oil seals will reduce the engine life.
Oil contamination from this and other sources within the engine bay has led to health concerns from some advocacy groups and has triggered research by several academic institutions and regulatory agencies. However, no credible research has yielded evidence for the existence of a medical condition caused by fume events.[6][7][8]
References
- ↑ Eitel, Elisabeth. CFD Software Models How Moving Parts Affect Aircraft-Cabin Airflow | Machine Design Magazine, 6 May 2014.
- ↑ Niren Laxmichand Nagda (Ed): Air Quality and Comfort in Airliner Cabins. ASTM International (2000) ISBN 978-0-8031-2866-8.
- ↑ "Cabin Air Quality." Statement of William W. Nazaroff, Ph.D. Professor of Environmental Engineering, University of California, Berkeley and Member, Committee on Air Quality in Passenger Cabins of Commercial Aircraft. (June 5, 2003)
- ↑ "CTT Systems AB receives cabin humidity control system order from Jet Aviation AG". Airline Industry Information, (March 5, 2007)
- ↑ The Guardian (2006-02-26). "Toxic cockpit fumes that bring danger to the skies". London. Retrieved 2007-10-20.
- ↑ Bagshaw, Michael (September 2008). "The Aerotoxic Syndrome" (PDF). European Society of Aerospace Medicine. Retrieved December 31, 2012.
- ↑ Select Committee on Science and Technology (2000). "Chapter 4: Elements Of Healthy Cabin Air". Science and Technology - Fifth Report (Report). House of Lords. Retrieved 2010-07-05.
- ↑ "Aircraft fumes: The secret life of BAe", "In the back" column, Private Eye magazine, issue 1193, 14–27 September 2007, pages 26–27; Pressdram Ltd., London.
- HVAC Applications volume of the ASHRAE Handbook, American Society of Heating, Ventilating and Air-Conditioning Engineers, Inc. (ASHRAE), Atlanta, GA, 1999.
External links
- This is ECS-An Aerospace Environmental Control Systems Consulting Firm
- Airbus ECS link
- Boeing ECS link
- Commercial airliner environmental control system
- Hamilton-Sundstrand ECS link
- Honeywell (formerly Allied-Signal) ECS link
- Liebherr ECS link
- JetAir ECS Resources link
|