Ice diving

Ice Diving - View from the top
Under the ice - view from below
Monitoring an ice diver conducting studies below the ice.
Cutting a hole in the ice to check the water conditions
Checking water conditions through a small hole in the ice
Cutting the ice hole with chainsaws

Ice diving is a type of penetration diving where the dive takes place under ice.[1][2] Because diving under ice places the diver in an overhead environment typically with only a single entry/exit point, it is considered an advanced type of diving requiring special training (although whether it constitutes technical diving is part of a wider debate within the diving community). Ice divers are generally tethered for safety. This means that the diver wears a special harness under the scuba unit. A line is secured to this harness, and the other end of the line is secured above the surface by one of a number of methods.

The diver also can use a weight harness, integrated weight buoyancy control device, or a weight belt with two buckles on it so the weights can not be accidentally released which would cause a run-away ascent into the ice sheet.

Ice diving is a team diving activity because the divers line requires a line tender. This person is responsible for paying out and taking in line so that the diver does not get tangled. Communication to the diver, or to the surface, is accomplished by pulling on the line. Each series of tugs means a different thing. There is a diver suited up and ready to enter the water at a moment's notice. This diver is a safety diver, and has his own tender. His purpose is to assist the primary diver in the event of a problem.

Divers who do not use a tether require extra training and full redundant scuba systems.

Polar diving experience has shown that buoyancy control is the critical skill affecting safety.[2]

Equipment

Since diving under the ice takes place in cold climates, there is typically a large amount of equipment required. Besides each person's clothing and exposure-protection requirements, including spare mitts and socks, there is basic scuba gear, back-up scuba gear, tools to cut a hole in the ice, snow removal tools, safety gear, some type of shelter, lines, and refreshments required.

Exposure suits

Because of the water temperature (between 4 °C and 0 °C in fresh water, approximately -1.9 °C for normal salinity sea water), exposure suits are mandatory.[3]

Some consider a dry suit mandatory; however, a thick wetsuit may be sufficient for hardier divers. A wetsuit can be pre-heated by pouring warm water into the suit. A hood and gloves (recommended three-finger mitts or dry gloves with rings) are necessary, and dry suit divers have the option of using hoods and gloves that keep their head and hands dry. Some prefer to use a full face diving mask to essentially eliminate any contact with the cold water. The biggest drawback to using a wet suit is the chilling effect on the diver caused by the water evaporating from the suit after a dive. This can be reduced by using a heated shelter.

Scuba equipment

A diving regulator suitable for cold-water is used. All regulators have a risk of freezing and free flowing, but some models fare better than others.[4] Environmentally sealed regulators avoid contact between the surrounding water and the moving parts of the first stage by isolating them in an antifreeze fluid (e.g. Poseidon)[1] or by siting the moving parts behind a diaphragm and transmitting the pressure through a pushrod (e.g. Apeks).

Although there is no universally accepted standard, at least one agency[5] recommends the use of two non-freezing regulators arranged as follows: primary first stage with primary second stage, BCD inflation hose, and submersible pressure gauge (SPG); secondary first stage with secondary second stage (octopus), dry suit inflation hose, and SPG, although only one SPG is needed for a single cylinder or manifolded twins.

The two first stages are mounted on independently closable valves, as a first stage freeze free-flow can only be stopped by shutting off the air supply from the cylinder until the valve has thawed out. The second regulator is there to supply the remaining gas when the first regulator is shut off. A second-stage isolation valve used in conjunction with a first-stage overpressure relief valve may be effective as a quick method to manage demand valve free-flow.[2]

Redundant systems usually typically comprise double cylinders with a primary and alternate regulator. Each of the 2nd stages is supplied its own first stage, which can be shut down at the cylinder valve in an emergency, such as a free flow. The diver’s bcd is on a different 1st stage to the drysuit so if there is an issue with one the diver can still control his buoyancy.

Most divers also use a primary regulator on a 7-foot hose and a secondary on a necklace, this is especially important when not using tethers so the divers can swim in a horizontal line. the reason for the primary being on a long hose is to ensure the diver who has an issue will get a known good regulator. Also there is less chance of the donor rolling off the regulator that was given to the diver in the emergency situation.

Buoyancy and weighting

Surface team.

  • Warm waterproof shoes.
  • Warm anorak for cold weather.
  • Warm cap covering the ears.
  • Sunglasses with a UV filter to protect the eyes in sunny days.
  • Lip-care stick and cream to protect hands and face against cold and wind.
  • A device like crampons to aid in traction on ice. especially when cutting the hole or carrying gear

Procedures and precautions

A guide line can be used as a reference for the divers to find the hole after the dive or in an emergency in a similar way to cave diving or wreck penetration.

Training

Training includes learning about how ice forms, how to recognize unsafe ice conditions, dive site preparation, equipment requirements, and safety drills.

Other skills required by the ice diver include:

Hazards

Hazards of ice diving include the general hazards of penetration diving, and some hazards that are more specific to the low temperature and overhead environment.

Regulator freezing

When air expands during pressure reduction in a regulator, the temperature drops and heat is absorbed from the surroundings.[7] There are two possible ways for a regulator to freeze and free-flow.

First stage freeze

Air from the diving cylinder is subjected to a dramatic reduction in pressure - as much as 220 bar from a full 230 bar cylinder at the surface - when passing through the regulator first stage. This lowers the temperature of the air, and heat is absorbed from the components of the regulator. As these components are largely metal and therefore good conductors of heat energy, the regulator body will cool quickly to a temperature lower than the surrounding medium. When immersed in water during a dive, the water surrounding the regulator is cooled and, if this water is already very cold, it can freeze.

If the water in direct contact with the pressure transfer mechanism (diaphragm or piston and the spring balancing the internal pressure) of the regulator freezes, the mechanism will be locked in the position at which the freezing takes place, as the ice will prevent the movement required to close. Since the cooling takes place during flow through the regulator, it is common for the freezing to occur when the first stage valve is open, and this will freeze the valve open, allowing a continuous flow through the first stage. This will cause the interstage pressure to rise until the second stage opens to relieve the excess pressure, the pressure relief valve on the first stage opens, or a low pressure hose or fitting bursts. All of these effects will allow the flow through the first stage to continue, so the cooling will continue, and this will keep the ice causing the problem frozen. To break the cycle it is necessary to stop the gas flow or expose the ice to a heat source capable of melting it. While underwater, it is unlikely to find a heat source to thaw the ice and stopping the flow is only option. Clearly the flow will stop when the pressure in the cylinder drops to ambient, but this is undesirable as it means total loss of the breathing gas. The other option is to close the cylinder valve, shutting off the pressure at the source. Once this is done, the ice will normally melt as heat from the surrounding water is absorbed by the slightly colder ice, and once the ice has melted, the regulator will function again.

This freezing can be avoided by preventing water from coming into direct contact with cooled moving parts of the regulator mechanism,[1][8] or by increasing the heat flow from the surrounding environment so that freezing does not occur.[9] Both strategies are used in regulator design.

Second stage freeze

A similar effect occurs with the second stage. Air which has already expanded and cooled through the first stage expands again and cools further at the demand valve of the second stage. This cools the components of the second stage and water in contact with them may freeze. Metal components around the moving parts of the valve mechanism allow heat transfer from the surrounding slightly warmer water, and from exhaled air from the diver, which is considerably warmer than the surroundings.

A second stage freeze is also likely to happen with the valve open, causing a free flow, which may precipitate a first stage freeze if not immediately stopped. If the flow through the frozen second stage can be stopped before the first stage freezes, the process can be halted. This may be possible if the second stage is fitted with a shutoff valve, but if this is done, the first stage must be fitted with an overpressure valve, as closing the supply to the second stage disables its secondary function as an overpressure valve.

Factors increasing the risk of regulator freeze

  • Purging
  • Buddy breathing
  • Octo breathing
  • Filling a lift bag or DSMB from the breathing regulator[1]
  • long bursts of dry suit inflation or BC inflation while breathing from the same regulator.
  • High breathing rate due to exertion
  • Water directly under the ice is likely to be colder than deeper water in fresh water.

Precautions to reduce risk of regulator freezing

  • Not breathing from the regulator until underwater. When testing the regulator before the dive, inhale only, avoid exhaling through the regulator as the moisture in the breath will freeze in the demand valve.[10]

Procedures for managing a regulator freeze

Protocol for a regulator freeze often includes aborting the dive.[10]

Procedures for managing low pressure inflator freeze

It is possible for your drysuit or bcd to freeze while inflating, if this happens it is critical to deal with this immediately. If this happens the best solution is to disconnect the low pressure inflator hose to what ever device is inflating while dumping air. After dumping air it is easy to become more negative so it is critical to have at least 2 buoyancy systems. like a drysuit and BCD. remember that if your drysuit inflator freezes open, it will allow water to seep in once disconnected so this usually causes the diver to end the dive.

most inflator problems can be avoided by:

References

  1. 1 2 3 4 Lang, M.A. & J. R. Stewart (eds.). (1992). AAUS Polar Diving Workshop Proceedings. United States: Scripps Institution of Oceanography, La Jolla, CA. p. 100. Retrieved 2008-08-07.
  2. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Lang, M.A. and M.D.J. Sayer (eds.) (2007). Proceedings of the International Polar Diving Workshop. Svalbard: Smithsonian Institution. pp. 211–213. Retrieved 2008-08-07.
  3. Lang, M.A. & Mitchell, C.T. (ed) (1987). AAUS Proceedings of Special Sesson on Coldwater Diving. United States: University of Washington, Seattle, WA. p. 122. Retrieved 2008-08-07.
  4. Clarke, John (2015). "Authorized for cold-water service: What Divers Should Know About Extreme Cold". ECO Magazine: 20–25. Retrieved 2015-03-07.
  5. Jablonski, Jarrod (2006). Doing it Right: The Fundamentals of Better Diving. Global Underwater Explorers. p. 92. ISBN 0971326703. To provide additional redundancy when using two first stages, the inflator hose should always be run from the right post. This requirement is illustrated in the case of a diver’s left post rolling off or breaking. If the inflator is run from the left post, the diver will simultaneously lose not only the use of the backup regulator around the neck but also the ability to inflate the BC. These two problems together could be inordinately compounded by an out-of-air situation in which a diver would not only be without the means of controlling his/her buoyancy but would also be deprived of the use of a third regulator
  6. Lee H. Somers, (1987a) Training scientific divers for work in cold water and polar environments. 1987 AAUS - Cold Water Diving Workshop. Ed. Michael A. Lang, Charles T. Mitchell, American Academy of Underwater sciences, Costa Mesa, California
  7. Salzman, WR. "Joule Expansion". Department of Chemistry, University of Arizona.
  8. In the Apeks Dry-Sealed System hydrostatic pressure, acting on the outer sealing diaphragm, is transmitted to the primary diaphragm via the load transmitter. http://www.apeks.co.uk/products/product_cats.asp?Lan=ENG&Category=First Stages, accessed 27 May 2012
  9. Poseidon Xstream uses large slots in the cover, to allow the heat energy of the ambient water to reach the spring and insulation to thermally isolate the inside components from the spring. The manufacturer claims that the regulator can free-flow air in fresh water of 0°C (32°F) for at least 10 minutes and be completely unaffected. X-stream user manual page 11, http://www.poseidon.com/sites/all/files/xstream_english.pdf accessed 27 May 2012
  10. 1 2 3 4 5 6 7 8 Lee H. Somers The under ice dive, (1987b), AAUS - Cold Water Diving Workshop, Ed. Michael A. Lang, Charles T. Mitchell, American Academy of Underwater sciences, Costa Mesa, California

External links

This article is issued from Wikipedia - version of the Sunday, April 17, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.