Murray loop bridge

Murray loop bridge
Leeds & Northrup test instrument capable of performing Murray and Varley loop tests.

Murray loop bridge is a bridge circuit used for locating faults in underground or underwater cables.[1] It has been used for more than 100 years.[2]

One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted. The bridge is brought to balance by changing the values of RB1 and RB2, which is achieved when:

\frac{R_x}{R_g + R_y} = \frac{R_{B1}}{R_{B2}}

which is equivalent to:

R_x = (R_g + R_y) \cdot \frac{R_{B1}}{R_{B2}}

The value of resistance Rx is proportional the length Lx, thus the location of the fault can be calculated:

L_x = 2 \cdot L \cdot \frac{R_{B1}}{R_{B1}+R_{B2}}

where L is the total length of the cable under test - a value proportional to Rg.

The method assumes a single fault exists, of low resistance compared with the undamaged cable insulation resistance, and that the cable conductors have uniform resistance per unit length.

Varley loop

The similar Varley loop uses fixed resistors for RB1 and RB2, and inserts a variable resistor in the faulted leg. Test sets for cable testing can be connected for either bridge technique. If the fault resistance is high, the sensitivity of the Murray bridge is reduced and the Varley loop may be more suitable.

See also

References

  1. http://sciencelinks.jp/j-east/article/200324/000020032403A0828577.php Archived February 17, 2012 at the Wayback Machine
  2. Latimer Clark, Robert Sabine Electrical tables and formulæ: for use of telegraph inspectors and operators, E. & F.N. Spon, 1871 pp. 41-44
This article is issued from Wikipedia - version of the Tuesday, January 26, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.