Passive sign convention
In electrical engineering, the passive sign convention (PSC) is a sign convention or arbitrary standard rule adopted universally by the electrical engineering community for defining the sign of electric power in an electric circuit.[1] The convention defines electric power flowing out of the circuit into an electrical component as positive, and power flowing into the circuit out of a component as negative.[1] So a passive component which consumes power, such as an appliance or light bulb, will have positive power dissipation, while an active component, a source of power such as an electric generator or battery, will have negative power dissipation.[2] This is the standard definition of power in electric circuits; it is used for example in computer circuit simulation programs such as SPICE.
To comply with the convention, the direction of the voltage and current variables used to calculate power and resistance in the component must have a certain relationship: the current variable must be defined so positive current enters the positive voltage terminal of the device.[3] These directions may be different from the directions of the actual current flow and voltage.
The convention
The passive sign convention states that in components in which the conventional current variable i is defined as entering the device through the terminal which is positive as defined by the voltage variable v,[2][4] the power p and resistance r are given by[5][6][7]
- and
In components in which the current i enters the device through the negative voltage terminal, power and resistance are given by
- and
With these definitions, passive components (loads) will have p > 0 and r > 0, and active components (power sources) will have p < 0 and r < 0.
Explanation
Active and passive components
In electrical engineering, power represents the rate of electrical energy flowing into or out of a given component or control volume. Power is a signed quantity; negative power just represents power flowing in the opposite direction from positive power. From the standpoint of power flow, electrical components in a circuit can be divided into two types:[2]
- In a load or passive component, such as a light bulb, resistor, or electric motor, electric current (flow of positive charges) moves through the device under the influence of the voltage in the direction of lower electric potential, from the positive terminal to the negative. So work is done by the charges on the component; potential energy flows out of the charges; and electric power flows from the circuit into the component, where it is converted to some other form of energy such as heat or mechanical work.
- In a source or active component, such as a battery or electric generator, current is forced to move through the device in the direction of greater electric potential energy, from the negative to the positive voltage terminal. This increases the potential energy of the electric charges, so electric power flows out of the component into the circuit. Work must be done on the moving charges by some source of energy in the component, to make them move in this direction against the opposing force of the electric field E.
Some components can be either a source or a load, depending on the voltage or current through them. For example a rechargeable battery acts as a source when it is used to produce power, but as a load when it is being recharged.
Since it can flow in either direction, there are two possible ways to define electric power; two possible reference directions: either power flowing into the circuit, or power flowing out of the circuit, can be defined as positive.[2] Whichever is defined as positive, the other will be negative. The passive sign convention arbitrarily defines power flowing out of the circuit (into the component) as positive,[2] so passive components have "positive" power flow.
Reference directions
The power flow p and resistance r of an electrical component are related to the voltage v and current i variables by the defining equation for power and Ohm's law:
Like power, voltage and current are signed quantities. The current flow in a wire has two possible directions, so when defining a current variable i the direction which represents positive current flow must be indicated, usually by an arrow on the circuit diagram.[8][9] This is called the reference direction for current i.[8][9] If the actual current is in the opposite direction, the variable i will have a negative value. Similarly in defining a voltage variable v, the terminal which represents the positive side must be specified, usually with an arrow or plus sign.[9] This is called the reference direction for voltage v.[8][9]
To understand the PSC, it is important to distinguish the reference directions of the variables, v and i, which can be assigned at will, from the direction of the actual voltage and current, which is determined by the circuit.[9] The idea of the PSC is that by assigning the reference direction of variables v and i in a component with the right relationship, the power flow in passive components calculated from Eq. (1) will come out positive, while the power flow in active components will come out negative. It is not necessary to know whether a component produces or consumes power when analyzing the circuit; reference directions can be assigned arbitrarily, directions to currents and polarities to voltages, then the PSC is used to calculate the power in components.[2] If the power comes out positive, the component is a load, converting electric power to some other kind of power. If the power comes out negative, the component is a source, converting some other form of power to electric power.
Sign conventions
The above discussion shows that choosing the relative direction of the voltage and current variables in a component determines the direction of power flow that is considered positive. The reference directions of the individual variables are not important, only their relation to each other. There are two choices:
- Passive sign convention: Defining the current variable as entering the positive terminal means that if the voltage and current variables have positive values, current flows from the positive to the negative terminal, doing work on the component, as occurs in a passive component. So power flowing into the component from the line is defined as positive; the power variable represents power dissipation in the component. Therefore
- Active components (power sources) will have negative resistance and negative power flow
- Passive components (loads) will have positive resistance and positive power flow
- This is the convention normally used.
- Active sign convention: Defining the current variable as entering the negative terminal means that if the voltage and current variables have positive values, current flows from the negative to the positive terminal, so work is being done on the current, and power flows out of the component. So power flowing out of the component is defined as positive; the power variable represents power produced. Therefore:
- Active components will have positive resistance and positive power flow
- Passive components will have negative resistance and negative power flow
- This convention is rarely used, except for special cases in power engineering.
In practice it is not necessary to assign the voltage and current variables in a circuit to comply with the PSC. Components in which the variables have a "backward" relationship, in which the current variable enters the negative terminal, can still be made to comply with the PSC by changing the sign of the constitutive relations (1) and (2) used with them.[5] A current entering the negative terminal is equivalent to a negative current entering the positive terminal, so in such a component[5][7]
- , and
Conservation of energy
One advantage of defining all the variables in a circuit to comply with the PSC is that it makes it easy to express conservation of energy. Since electric energy cannot be created or destroyed, at any given instant every watt of power consumed by a load component must be produced by some source component in the circuit. Therefore the sum of all the power consumed by loads equals the sum of all the power produced by sources. Since with the PSC the power dissipation in sources is negative and power dissipation in loads is positive, the sum of all the power dissipation in all the components in a circuit is always zero[7]
AC circuits
Since the sign convention only deals with the directions of the variables and not with the direction of the actual current, it also applies to alternating current (AC) circuits, in which the direction of the voltage and current periodically reverses. In AC circuits, even though the voltage and current reverse direction, a "formal" direction of current flow and voltage polarity are defined by considering the voltage and current direction in the first half of the cycle "positive". During the second half of the AC cycle, in a resistive AC circuit, both the voltage and current in the device reverse direction, so the sign of the voltage and current reverse. Since the power is the product of voltage and current, the two sign reversals cancel each other, and the sign of the power flow is unchanged.
Alternative convention in power engineering
In practice, the power output of power sources such as batteries and generators is not given in negative numbers, as required by the passive sign convention.[2] No manufacturer sells a "−5 kilowatt generator".[2] The standard practice in electric power circuits is to use positive values for the power and resistance of power sources, as well as loads. This avoids confusion over the meaning of "negative power", and particularly "negative resistance".[2] In order to make the power for both sources and loads come out positive, instead of the PSC, separate sign conventions must be used for sources and loads. These are called the "generator-load conventions"[10][11][12]
- Generator convention - In source components like generators and batteries, the variables V and I are defined according to the active sign convention above; the current variable is defined as entering the negative terminal of the device.[11]
- Load convention - In loads, the variables are defined according to the normal passive sign convention; the current variable is defined as entering the positive terminal.[11]
Using this convention, positive power flow in source components is power produced, while positive power flow in load components is power consumed. As with the PSC, if the variables in a given component do not conform to the applicable convention, the component can still be made to conform by using negative signs in the constitutive equations (1) and (2)
- and
This convention may seem preferable to the PSC, since the power P and resistance R always have positive values. However it cannot be used in electronics, because it is not possible to classify some electronic components unambiguously as "sources" or "loads". Some electronic components may act as sources of power with negative resistance in some portions of their operating range, and as absorbers of power with positive resistance in other portions, or even in different portions of the AC cycle. Whether the component acts as a source or load may depend on the current i or voltage v in it, which is not known until the circuit is analyzed. For example, if the voltage across a rechargeable battery's terminals is less than its open-circuit voltage, it will act as a source, while if the voltage is greater it will act as a load and recharge. So it is necessary for power and resistance variables to be able to take on both positive and negative values.
References
- 1 2 Kreith, l Frank; D. Yogi Goswami (2005). The CRC Handbook Of Mechanical Engineering, 2nd Ed. CRC Press. pp. 5.5–5.6. ISBN 0849308666.
- 1 2 3 4 5 6 7 8 9 Glisson, Tildon H. (2011). Introduction to Circuit Analysis and Design. USA: Springer. pp. 114–116. ISBN 9048194423.
- ↑ Eccles, William J. (2011). Pragmatic Electrical Engineering: Fundamentals. Morgan & Claypool Publishers. pp. 4–5. ISBN 1608456684.
- ↑ Traylor, Roger L. (2008). "Calculating Power Dissipation" (PDF). Lecture Notes - ECE112:Circuit Theory. Dept. of Elect. and Computer Eng., Oregon State Univ. Retrieved 23 October 2012.
- 1 2 3 Jamid, Housain A. (2008). "Class Notes, Class 2, p.5" (PDF). EE 201: Electric Circuits. Open Courseware, King Fahd Univ. of Petroleum and Minerals, Saudi Arabia. Retrieved 23 October 2012. External link in
|publisher=
(help) - ↑ Shattuck, Dave (2011). "Set #5 - Introduction to Circuit Analysis" (PPT). ECE 1100: Introduction to Electrical and Computer Engineering. Cullen College of Engineering, Univ. of Houston. Retrieved March 25, 2013. External link in
|publisher=
(help), p. 17 - 1 2 3 Prasad, Shalini (2010). "Basic Concepts Overview" (PDF). Class notes ECE 221: Electric Circuit Analysis. Dept. of Electrical and Computer Engineering, Portland State Univ. Retrieved March 25, 2013., p.13-16
- 1 2 3 O'Malley, John (1992). Schaum's Outline of Basic Circuit Analysis, 2nd Ed. McGraw Hill Professional. pp. 2–4. ISBN 0070478244.
- 1 2 3 4 5 Kumar, K. S. Suresh (2008). Electric Circuits & Networks. Pearson Education India. pp. 26–28. ISBN 8131713903.
- ↑ Glover, J. Duncan; Mulukutla S. Sarma; Thomas Jeffrey Overbye (2011). Power System Analysis and Design, 5th Ed. Cengage Learning. pp. 53–54. ISBN 1111425779.
- 1 2 3 Lukman, Dedek (March 2002). "Loss minimization in the modified algorithm of load flow analysis in industrial power system". Master's Thesis. Dept. of Electrical Engineering and Telecommunications, Univ. of New South Wales website. Retrieved January 13, 2013., p.7
- ↑ "Power Flow Sign Convention, p.12". Tutorial on Phasor, Single, and Three Phase Circuits, EE2751: Electrical Energy Systems. Dept. of Electrical Engineering, Hong Kong Polytechnic Univ. website. January 2009. Retrieved January 13, 2013.