Superinsulation

The passivhaus standard combines superinsulation with other techniques and technologies to achieve ultra-low energy use.

Superinsulation is an approach to building design, construction, and retrofitting that dramatically reduces heat loss (and gain) by using much higher levels of insulation and airtightness than normal. Superinsulation is one of the ancestors of the passive house approach.

Definition

There is no set definition of superinsulation, but superinsulated buildings typically include:

Nisson & Dutt (1985) suggest that a house might be described as "superinsulated" if the cost of space heating is lower than the cost of water heating.[1]

Theory

A superinsulated house is intended to reduce heating needs very significantly and may even be heated predominantly by intrinsic heat sources (waste heat generated by appliances and the body heat of the occupants) with very small amounts of backup heat. This has been demonstrated to work even in very cold climates but requires close attention to construction details in addition to the insulation (see IEA Solar Heating & Cooling Implementing Agreement Task 13).

History

The term "superinsulation" was coined by Wayne Schick at the University of Illinois at Urbana-Champaign. In 1976 he was part of a team that developed a design called the "Lo-Cal" house, using computer simulations based on the climate of Madison, Wisconsin. Several houses, duplexes and condos based on Lo-Cal principles were built in Champaign-Urbana, Illinois in the 1970s.[2][3]

In 1977 the "Saskatchewan House"[4] was built in Regina, Saskatchewan by a group of several Canadian government agencies. It was the first house to publicly demonstrate the value of superinsulation and generated a lot of attention. It originally included some experimental evacuated-tube solar panels, but they were not needed and were later removed. The house was heated primarily by waste heat from appliances and the occupants.[3][5]

In 1977 the "Leger House" was built by Eugene Leger, in East Pepperell, Massachusetts. It had a more conventional appearance than the "Saskatchewan House", and also received extensive publicity.[3]

Publicity from the "Saskatchewan House" and the "Leger House" influenced other builders, and many superinsulated houses were built over the next few years. These houses also influenced Wolfgang Feist when he developed the Passivhaus standard.[3]

Retrofits

It is possible, and increasingly desirable, to retrofit superinsulation to an existing houses or buildings. The easiest way is often to add layers of continuous rigid exterior insulation,[6] and sometimes by building new exterior walls that allow more space for insulation. A vapor barrier can be installed on the outside of the original framing but may not be needed. An improved continuous air barrier is almost always worth adding, as older homes tend to be leaky, and such an air barrier can be important for energy savings and durability. Care should be exercised when adding a vapor barrier as it can reduce drying of incidental moisture, or even cause summer (in climates with humid summers) interstitial condensation and consequent mold and mildew. This may cause health problems for the occupants and damage the existing structure. Many builders in northern Canada use a simple 1/3 to 2/3 approach, placing the vapor barrier no further out than 1/3 of the R-value of the insulated portion of the wall. This method is generally valid for interior walls that have little or no vapor resistance (e.g. they use fibrous insulation) and controls air leakage condensation as well as vapor diffusion condensation. This approach will ensure that condensation does not occur on or to the inside of the vapor barrier during cold weather. The 1/3:2/3 rule will ensure that the vapor barrier temperature will not fall below the dew point temperature of the interior air, and will minimize the possibility of cold-weather condensation problems. For example, with an internal room temperature of 20°C (68°F), the vapor barrier will then only reach 7.3 °C (45 °F) when the outside temperatures is at −18°C (-1°F). Indoor air dewpoint temperatures are more likely to be in the order of around 0 °C (32 °F) when it is that cold outdoors, much lower than the predicted vapor barrier temperature, and hence the 1/3:2/3 rules is quite conservative. For climates that do not often experience -18°C, the 1/3:2/3 rule should be amended to 40:60% or 50:50. As the interior air dewpoint temperature is an important basis for such rules, buildings with high interior humidities during cold weather (e.g., museums, swimming pools, humdified or poorly ventilated airtight homes) may require different rules, as can buildings with drier interior environments (such as highly ventilated buildings, warehouses). The 2009 International Residential Code (IRC) embodies more sophisticated rules to guide the choice of insulation on the exterior of new homes, which can be applied when retrofitting older homes.

A vapor permeable building wrap on the outside of the original wall helps keep the wind out, yet allows the wall assembly to dry to the exterior. Asphalt felt and other products such as permeable polymer based products are available for this purpose, and usually double as the Water Resistant Barrier / drainage plane as well.

Interior retrofits are possible where the owner wants to preserve the old exterior siding, or where setback requirements don't leave space for an exterior retrofit. Sealing the air barrier is more difficult and the thermal insulation continuity compromised (because of the many partition, floor, and service penetrations), the original wall assembly is rendered colder in cold weather (and hence more prone to condensation and slower to dry), occupants are exposed to major disruptions, and the house is left with less interior space. Another approach is to use the 1/3 to 2/3 method mentioned above — that is, to install a vapor retarder on the inside of the existing wall (if there isn't one there already) and add insulation and support structure to the inside. This way, utilities (power, telephone, cable, and plumbing) can be added in this new wall space without penetrating the air barrier. Polyethylene vapor barriers are risky except in very cold climates, because they limit the wall's ability to dry to the interior. This approach also limits the amount of interior insulation that can be added to a rather small amount (e.g., only R6 can be added to a 2x4 R12 wall).

Costs and benefits

In new construction, the cost of the extra insulation and wall framing may be offset by not requiring a dedicated central heating system. In homes with numerous rooms, more than one floor, air conditioning or large sized, a central furnace is often justified or required to ensure sufficiently uniform temperatures. Small furnaces are not very expensive and some ductwork to every room is almost always required to provide ventilation air in any case. When peak demand and annual energy use is low, sophisticated and expensive central heating systems are not often required. Hence, even electric resistance heaters may be used. Electric heaters are typically only used on the coldest winter nights when overall demand for electricity is low. Other forms of backup heater are widely used, such as wood pellets, wood stoves, natural gas boilers or even furnaces. The cost of a superinsulation retrofit should be balanced against the future cost of heating fuel (which can be expected to fluctuate from year to year due to supply problems, natural disasters or geopolitical events), the desire to reduce pollution from heating a building, or the desire to provide exceptional thermal comfort.

During a power failure, a superinsulated house stays warm longer as heat loss is much less than normal, but the thermal storage capacity of the structural materials and contents is the same. Adverse weather may hamper efforts to restore power, leading to outages lasting a week or more. When deprived of their continuous supply of electricity (either for heat directly, or to operate gas-fired furnaces), conventional houses cool rapidly during, and may be at greater risk of costly damage due to freezing water pipes. Residents who use supplemental heating methods without proper care during such episodes, or at any other time, may subject themselves to risk of fire or carbon monoxide poisoning.

See also

The first superinsulated houses used standard stud-wall construction, but other building techniques can be used:

Notes

  1. Nisson, J. D. Ned; and Gautam Dutt, The Superinsulated Home Book, John Wiley & Sons, 1985 ISBN 0-471-88734-X, ISBN 0-471-81343-5
  2. McCulley, M. (2008, November). Pioneering superinsulation and the Lo-Cal House: Design, construction, evaluation and conclusions. Paper presented at the 3rd Annual North American Passive House Conference, Duluth, MN
  3. 1 2 3 4 Denzer, Anthony (2013). The Solar House: Pioneering Sustainable Design. Rizzoli. ISBN 978-0847840052.
  4. Ralko, Joe. The Encyclopedia of Saskatchewan http://esask.uregina.ca/entry/energy-efficient_houses.html. Retrieved 1 February 2016. Missing or empty |title= (help)
  5. Holladay, Martin (April 17, 2009). "Forgotten Pioneers of Energy Efficiency". GreenBuildingAdvisor.com.
  6. Ueno, K., "Residential Exterior Wall Superinsulation Retrofit Details and Analysis", ASHRAE Buildings 11 Conference, 2010. http://www.buildingscience.com/documents/reports/rr-1012-residential-exterior-wall-superinsulation-retrofit

References

  • Computation and description of an outside insulation house: To build for tomorrow (translated from French)
  • Booth, Don, Sun/Earth Buffering and Superinsulation, 1983, ISBN 0-9604422-4-3
  • Marshall, Brian; and Robert Argue, The Super-Insulated Retrofit Book, Renewable Energy in Canada, 1981 ISBN 0-920456-45-6, ISBN 0-920456-43-X
  • Shurcliff, William A., Superinsulated houses: A survey of principles and practice, Brick House Pub. Co, 1981, 1982 ISBN 0-931790-25-5
  • Shurcliff, William A., Superinsulated Houses and Air-To-Air Heat Exchangers, Brick House Pub Co, 1988, ISBN 0-931790-73-5

External links

This article is issued from Wikipedia - version of the Tuesday, February 02, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.