Tamworth rail crash

Tamworth rail crash
Date 14 September 1870
Time 4:09 am
Location Tamworth (low level) railway station
Country England
Rail line Trent Valley Line
Operator London and North Western Railway
Cause Signalling error
Statistics
Trains 1
Deaths 3
Injuries 13
List of UK rail accidents by year

The Tamworth rail crash was an accident that happened at Tamworth railway station in Staffordshire, England, on 14 September 1870. It was caused when a signalmans error accidentally diverted the Irish Mail express onto a dead end siding, where part of the train crashed through the buffers and into the River Anker. Three people were killed, and thirteen injured.

Setting

At Tamworth low level station in 1870, there were two running lines through the station, with two platform loops diverging at each side, serving each platform. At the end of the up (London bound) platform loop, was a dead end siding leading to a pumphouse by the River Anker with a small reservoir alongside it.

The points exiting the up platform loop onto the running line, were interlocked with those into the siding, meaning that when the points were set to allow trains through on the running line, the points would also be automatically set to divert any trains running forward on the loop into the siding, to prevent them from accidentally running onto the running line. There were two signalboxes at the north and south ends of the station, each controlling the points and signals from either direction.

The accident

On the 14 September, the Irish Mail had been delayed by the late running of the steamer at Holyhead, and it was thirteen minutes late by the time it approached Tamworth. The signalman in the south signalbox was expecting the Mail, and had correctly set his points to allow it through on the running line, which also set the points on the loop into the siding. The signalman in the north signalbox however became confused after his watch had stopped, and was expecting a goods train, and set his points into the loop.

At around 4:09 am the Mail approached Tamworth at around 50mph (85 kmh), the driver saw that the signal was set for the loop and applied the emergency brakes, but could not stop before being diverted onto the platform loop and then into the siding. The train had slowed down to about 15 mph when it hit the buffer stop at the end of the siding. The locomotive went through the buffers and crashed into the River Anker. A coach and a postal van overturned into the reservoir. The driver and fireman on the engine, and one passenger were killed. Thirteen other people were injured, including ten passengers, two postal staff, and a guard who was seriously injured.

Report

The accident report criticised the poor interlocking and signalling arrangements at the station, specifically the lack of interlocking between the north and south signalboxes to prevent an accident of this type from occurring. It also criticised the lack of sufficient warning to the engine driver that the points were set the wrong way, and also the lack of information about train movements; telegraph equipment had been installed at both signalboxes at the time of the accident, but was not in use.

The report also noted that the accident would have been considerably worse had the Mail not been fitted with continuous brakes, and noted that it might have stopped short of the buffers had the rails not been greasy.

Reference

External links

This article is issued from Wikipedia - version of the Friday, June 05, 2015. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.