Thermal resistance

Thermal resistance is a heat property and a measurement of a temperature difference by which an object or material resists a heat flow. Thermal resistance is the reciprocal of thermal conductance.

Absolute thermal resistance

Absolute thermal resistance is the temperature difference across a structure when a unit of heat energy flows through it in unit time. It is the reciprocal of thermal conductance. The SI units of thermal resistance are kelvins per watt or the equivalent degrees Celsius per watt (the two are the same since the intervals are equal: Δ1 K = Δ1 °C).

The thermal resistance of materials is of great interest to electronic engineers because most electrical components generate heat and need to be cooled. Electronic components malfunction or fail if they overheat, and some parts routinely need measures taken in the design stage to prevent this.

Analogies

Main article: hydraulic analogy

Electronic engineers are familiar with Ohm's law and so often use it as an analogy when doing calculations involving thermal resistance. Mechanical and Structural engineers are more familiar with Hooke's law and so often use it as an analogy when doing calculations involving thermal resistance.

type structural analogy[1] hydraulic analogy thermal electrical analogy[2]
quantity ... ... [...] m3 of water heat Q [J] charge q [C]
potential displacement X [m] pressure P [N/m2] temperature T [K=J/k_B] potential V [V=J/C]
flux load or force F [N] flow rate Q [m3/s] heat transfer rate \dot{Q} [W=J/s] current I [A=C/s]
flux density stress  \sigma [N/m2 = Pa] velocity [m/s] heat flux \overrightarrow{q} [W/m2] current density j [C/(m2·s) = A/m2]
resistance flexibility  1/k [...] fluid resistance R [...] thermal resistance R [...] electrical resistance R [Ω]
conductivity stiffness  k [N/m] thermal conductivity1/R [W/(K·m)] electrical conductance 1/R [...]
lumped element linear model Hooke's law \Delta X = F/k Hagen–Poiseuille equation \Delta P = Q R Newton's law of cooling \Delta T = \dot{Q} R Ohm's law \Delta V = IR
distributed linear model ... ... Fourier's law  \overrightarrow{q} = -  k {\nabla} T Ohm's law \mathbf{J} = \sigma \mathbf{E}

Explanation from an electronics point of view

Equivalent thermal circuits

The diagram shows an equivalent thermal circuit for a semiconductor device with a heat sink:
Q is the power dissipated by the device.
T_J is the junction temperature in the device.
T_C is the temperature at its case.
T_H is the temperature where the heat sink is attached.
T_{AMB} is the ambient air temperature.
R_{\theta JC} is the device's absolute thermal resistance from junction to case.
R_{\theta CH} is the absolute thermal resistance from the case to the heatsink.
R_{\theta HA} is the absolute thermal resistance of the heat sink.

The heat flow can be modelled by analogy to an electrical circuit where heat flow is represented by current, temperatures are represented by voltages, heat sources are represented by constant current sources, absolute thermal resistances are represented by resistors and thermal capacitances by capacitors.

The diagram shows an equivalent thermal circuit for a semiconductor device with a heat sink.

Example calculation

Consider a component such as a silicon transistor that is bolted to the metal frame of a piece of equipment. The transistor's manufacturer will specify parameters in the datasheet called the absolute thermal resistance from junction to case (symbol: R_{\theta JC}), and the maximum allowable temperature of the semiconductor junction (symbol: T_{JMAX}). The specification for the design should include a maximum temperature at which the circuit should function correctly. Finally, the designer should consider how the heat from the transistor will escape to the environment: this might be by convection into the air, with or without the aid of a heat sink, or by conduction through the printed circuit board. For simplicity, let us assume that the designer decides to bolt the transistor to a metal surface (or heat sink) that is guaranteed to be less than \Delta T_{HS} above the ambient temperature. Note: THS appears to be undefined.

Given all this information, the designer can construct a model of the heat flow from the semiconductor junction, where the heat is generated, to the outside world. In our example, the heat has to flow from the junction to the case of the transistor, then from the case to the metalwork. We do not need to consider where the heat goes after that, because we are told that the metalwork will conduct heat fast enough to keep the temperature less than \Delta T_{HS} above ambient: this is all we need to know.

Suppose the engineer wishes to know how much power he can put into the transistor before it overheats. The calculations are as follows.

Total absolute thermal resistance from junction to ambient = R_{\theta JC}+R_{\theta B}

where R_{\theta B} is the absolute thermal resistance of the bond between the transistor's case and the metalwork. This figure depends on the nature of the bond - for example, a thermal bonding pad or thermal transfer grease might be used to reduce the absolute thermal resistance.

Maximum temperature drop from junction to ambient = T_{JMAX}-(T_{AMB}+\Delta T_{HS}).

We use the general principle that the temperature drop \Delta T across a given absolute thermal resistance R_{\theta} with a given heat flow Q through it is:

\Delta T = Q \times R_{\theta}\,.

Substituting our own symbols into this formula gives:

T_{JMAX}-(T_{AMB}+\Delta T_{HS})=Q_{MAX} \times (R_{\theta JC}+R_{\theta B}+R_{\theta HA})\,,

and, rearranging,


   Q_{MAX} = 
   { 
     { T_{JMAX}-(T_{AMB}+\Delta T_{HS}) } \over { R_{\theta JC}+R_{\theta B}+R_{\theta HA} }
   }

The designer now knows Q_{MAX}, the maximum power that the transistor can be allowed to dissipate, so he can design the circuit to limit the temperature of the transistor to a safe level.

Let us substitute some sample numbers:

T_{JMAX} = 125 \ ^{\circ}\mbox{C} (typical for a silicon transistor)
T_{AMB} = 21 \ ^{\circ}\mbox{C} (a typical specification for commercial equipment)
R_{\theta JC} = 1.5 \ ^{\circ}\mathrm{C}/\mathrm{W} \, (for a typical TO-220 package)
R_{\theta B} = 0.1 \ ^{\circ}\mathrm{C}/\mathrm{W} \, (a typical value for an elastomer heat-transfer pad for a TO-220 package)
R_{\theta HA} = 4 \ ^{\circ}\mathrm{C}/\mathrm{W} \, (a typical value for a heatsink for a TO-220 package)

The result is then:

Q = {{125-(21)} \over {1.5+0.1+4}} = 18.6 \ \mathrm{W}

This means that the transistor can dissipate about 18 watts before it overheats. A cautious designer would operate the transistor at a lower power level to increase its reliability.

This method can be generalised to include any number of layers of heat-conducting materials, simply by adding together the absolute thermal resistances of the layers and the temperature drops across the layers.

Derived from Fourier's Law for heat conduction

From Fourier's Law for heat conduction, the following equation can be derived, and is valid as long as all of the parameters (x and k) are constant throughout the sample.

 R_{\theta} = \frac{x}{A \times k}

where:

Problems with electrical resistance analogy

A 2008 review paper written by Phillips researcher Clemens J. M. Lasance notes that: "Although there is an analogy between heat flow by conduction (Fourier’s law) and the flow of an electric current (Ohm’s law), the corresponding physical properties of thermal conductivity and electrical conductivity conspire to make the behavior of heat flow quite unlike the flow of electricity in normal situations. [...] Unfortunately, although the electrical and thermal differential equations are analogous, it is erroneous to conclude that there is any practical analogy between electrical and thermal resistance. This is because a material that is considered an insulator in electrical terms is about 20 orders of magnitude less conductive than a material that is considered a conductor, while, in thermal terms, the difference between an "insulator" and a "conductor" is only about three orders of magnitude. The entire range of thermal conductivity is then equivalent to the difference in electrical conductivity of high-doped and low-doped silicon."[3]

Measurement standards

The junction-to-air thermal resistance can vary greatly depending on the ambient conditions.[4] (A more sophisticated way of expressing the same fact is saying that junction-to-ambient thermal resistance is not Boundary-Condition Independent (BCI).[3]) JEDEC has a standard (number JESD51-2) for measuring the junction-to-air thermal resistance of electronics packages under natural convection and another standard (number JESD51-6) for measurement under forced convection.

A JEDEC standard for measuring the junction-to-board thermal resistance (relevant for surface-mount technology) has been published as JESD51-8.[5]

A JEDEC standard for measuring the junction-to-case thermal resistance (JESD51-14) is relatively newcomer, having been published in late 2010; it concerns only packages having a single heat flow and an exposed cooling surface.[6][7][8]

Resistance in Composite Wall

Parallel thermal resistance

Similarly to electrical circuits, the total thermal resistance for steady state conditions can be calculated as follows.

Parallel Thermal Resistance in composite walls

The total thermal resistance

 { {1\over R_{tot}} =  {1\over R_B} + {1\over R_C} }          (1)

Simplifying the equation, we get

 {R_{tot}= {R_B R_C\over R_B+R_C} }           (2)

With terms for the thermal resistance for conduction, we get

 {R_{t,cond}= {L\over (k_b+k_c)A}}          (3)

Resistance in series and parallel

It is often suitable to assume one-dimensional conditions, although the heat flow is multidimensional. Now, two different circuits may be used for this case. For case (a) (shown in picture), we presume isothermal surfaces for those normal to the x- direction, whereas for case (b) we presume adiabatic surfaces parallel to the x- direction. We may obtain different results for the total resistance  {R_{tot} } and the actual corresponding values of the heat transfer are bracketed by  {q} . When the multidimensional effects becomes more significant, these differences are increased with increasing  {| k_f - k_g |} .[9]

Equivalent thermal circuits for series-parallel composite wall

Radial Systems

Spherical and cylindrical systems may be treated as one-dimensional, due to the temperature gradients in the radial direction. The standard method can be used for analyzing radial systems under steady state conditions, starting with the appropriate form of the heat equation, or the alternative method, starting with the appropriate form of Fourier’s law. For a hollow cylinder in steady state conditions with no heat generation, the appropriate form of heat equation is [9]

{ {1\over r}{d\over dr} \left(kr{dT\over dr} \right)= 0  }          (4)

Where  {k } is treated as a variable. Considering the appropriate form of Fourier’s law, the physical significance of treating  {k } as a variable becomes evident when the rate at which energy is conducted across a cylindrical surface, this is represented as

{ q_r = -kA {dT\over dr} = -k(2\pi rL){dT\over dr}}          (5)

Where  {A=2\pi rL} is the area that is normal to the direction of where the heat transfer occurs. Equation 1 implies that the quantity  {kr(dT/dr)} is not dependent of the radius  {r} , it follows from equation 5 that the heat transfer rate,  {q_r } is a constant in the radial direction.

Hollow cylinder with convective surface conditions in thermal conduction

In order to determine the temperature distribution in the cylinder, equation 4 can be solved applying the appropriate boundary conditions. With the assumption that  {k } is constant

 { T(r) = C_1lnr + C_2}           (6)

Using the following boundary conditions, the constants  {C_1} and  {C_2} can be computed

 {   T(r_1)=T_{s,1}}          and           {T(r_2)=T_{s,2}    } 

The general solution gives us

 {  T_{s,1} = C_1 lnr_1 + C_2 }          and           {T_{s,1} = C_1lnr_2 + C_2    } 

Solving for  { C_1} and  { C_2} and substituting into the general solution, we obtain

 {   T(r) = {T_{s,1}- T_{s,2}\over  {ln(r_2/r_1) } } ln \left( {r \over r_2} \right) + T_{s,2}}           (7)

The logarithmic distribution of the temperature is sketched in the inset of the thumbnail figure. Assuming that the temperature distribution, equation 7, is used with Fourier’s law in equation 5, the heat transfer rate can be expressed in the following form

 {q_r = {2\pi Lk (T_{s,1}-T_{s,2}) \over ln(r_2/r_1)} } 

Finally, for radial conduction in a cylindrical wall, the thermal resistance is of the form

 { R_{t,cond}  = {ln(r_2/r_1) \over 2\pi Lk}               }

See also

References

  1. Tony Abbey. "Using FEA for Thermal Analysis". Desktop Engineering magazine. 2014 June. p. 32.
  2. "The Design of Heatsinks".
  3. 1 2 Lasance, C. J. M. (2008). "Ten Years of Boundary-Condition- Independent Compact Thermal Modeling of Electronic Parts: A Review". Heat Transfer Engineering 29 (2): 149. doi:10.1080/01457630701673188.
  4. Ho-Ming Tong; Yi-Shao Lai; C.P. Wong (2013). Advanced Flip Chip Packaging. Springer Science & Business Media. pp. 460–461. ISBN 978-1-4419-5768-9.
  5. Younes Shabany (2011). Heat Transfer: Thermal Management of Electronics. CRC Press. pp. 111–113. ISBN 978-1-4398-1468-0.
  6. Clemens J.M. Lasance; András Poppe (2013). Thermal Management for LED Applications. Springer Science & Business Media. p. 247. ISBN 978-1-4614-5091-7.
  7. http://www.electronics-cooling.com/2013/02/experiment-vs-simulation-part-3-jesd51-14/
  8. Schweitzer, D.; Pape, H.; Chen, L.; Kutscherauer, R.; Walder, M. (2011). "Transient dual interface measurement — A new JEDEC standard for the measurement of the junction-to-case thermal resistance". 2011 27th Annual IEEE Semiconductor Thermal Measurement and Management Symposium. p. 222. doi:10.1109/STHERM.2011.5767204. ISBN 978-1-61284-740-5.
  9. 1 2 Incropera, Dewitt, Bergman, Lavine, Frank P., David P., Theodore L., Adrienne S. (2013). Principles of Heat and Mass Transfer,. John Wiley & Sons; 7th Edition, Interna edition. ISBN 978-0470646151.

Further reading

There is a large amount of literature on this topic. In general, works using the term "thermal resistance" are more engineering-oriented, whereas works using the term thermal conductivity are more [pure-]physics-oriented. The following books are representative, but may be easily substituted.

External links

This article is issued from Wikipedia - version of the Friday, February 19, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.