Desorption/ionization on silicon
Acronym | DIOS |
---|---|
Classification | Mass spectrometry |
Analytes |
Organic molecules Biomolecules Polymers |
Other techniques | |
Related |
MALDI Soft laser desorption |
Desorption/ionization on silicon (DIOS) is a soft laser desorption method used to generate gas-phase ions for mass spectrometry. It is a matrix-free technique in which a sample is deposited on porous silicon and desorbed from the silicon surface by a laser. DIOS can be used to analyze organic molecules, biomolecules and peptides, and to image cells.
Background
Soft laser desorption is a soft ionization technique. It ionizes molecules with minimal fragmentation. This is useful for larger molecules and molecules that fragment easily. The first soft laser desorption technique was Matrix-assisted laser desorption/ionization (MALDI). In MALDI, the analyte is first mixed with a matrix solution. The matrix absorbs energy from the laser pulse and transfers it to the analyte, causing desorption and ionization of the sample. MALDI generates [M+H]+ ions.[1]
DIOS was first reported by Gary Siuzdak, Jing Wei and Jillian M. Buriak in 1999. It was developed as a matrix free alternative to MALDI for smaller molecules. Because MALDI uses a matrix, background ions are introduced due to ionization of the matrix. These ions reduce the usefulness of MALDI for small molecules. In contrast, DIOS uses a porous silicon surface to trap the analyte. This surface is not ionized by the laser, allowing for the analysis of small molecules.[2][3][4]
Applications
DIOS has been shown to detect peptides, natural products, small organic molecules, and polymers with little fragmentation.[5]
DIOS can be used for proteomics. It has been reported as a useful method protein identification. Because it is matrix free, it can be used to identify smaller biomolecules than MALDI. In addition, it can be used to monitor reactions on a single surface through repeated MS analyses. Reaction monitoring can be used to screen enzyme inhibitors.[6]
Atmospheric pressure DIOS was shown to be an effective tool for quantitative analysis of drugs with high proton affinity.[7]
The use of DIOS to image small molecules has been demonstrated. Lin He and coworkers imaged small molecules on mouse liver cells. They also used marker molecules to image HEK 293 cancer cells.[8]
References
- ↑ Karas, Michael; Krüger, Ralf (2003). "Ion Formation in MALDI: The Cluster Ionization Mechanism". Chemical Reviews 103 (2): 427–440. doi:10.1021/cr010376a. ISSN 0009-2665.
- ↑ Lewis, Warren G.; Shen, Zhouxin; Finn, M.G.; Siuzdak, Gary (2003). "Desorption/ionization on silicon (DIOS) mass spectrometry: background and applications". International Journal of Mass Spectrometry 226 (1): 107–116. doi:10.1016/S1387-3806(02)00973-9. ISSN 1387-3806.
- ↑ Buriak, Jillian M.; Wei, Jing; Siuzdak, Gary (1999). "Desorption-ionization mass spectrometry on porous silicon". Nature 399 (6733): 243–246. doi:10.1038/20400. ISSN 0028-0836. PMID 10353246.
- ↑ Peterson, Dominic S. (2007). "Matrix-free methods for laser desorption/ionization mass spectrometry". Mass Spectrometry Reviews 26 (1): 19–34. doi:10.1002/mas.20104. ISSN 0277-7037.
- ↑ Shen, Zhouxin; Thomas, John J.; Averbuj, Claudia; Broo, Klas M.; Engelhard, Mark; Crowell, John E.; Finn, M. G.; Siuzdak, Gary (2001). "Porous Silicon as a Versatile Platform for Laser Desorption/Ionization Mass Spectrometry". Analytical Chemistry 73 (3): 612–619. doi:10.1021/ac000746f. ISSN 0003-2700.
- ↑ Thomas, J. J.; Shen, Z.; Crowell, J. E.; Finn, M. G.; Siuzdak, G. (2001). "Desorption/ionization on silicon (DIOS): A diverse mass spectrometry platform for protein characterization". Proceedings of the National Academy of Sciences 98 (9): 4932–4937. doi:10.1073/pnas.081069298. ISSN 0027-8424.
- ↑ Huikko, K.; Östman, P.; Sauber, C.; Mandel, F.; Grigoras, K.; Franssila, S.; Kotiaho, T.; Kostiainen, R. (2003). "Feasibility of atmospheric pressure desorption/ionization on silicon mass spectrometry in analysis of drugs". Rapid Communications in Mass Spectrometry 17 (12): 1339–1343. doi:10.1002/rcm.1051. ISSN 0951-4198.
- ↑ Liu, Qiang; Guo, Zhong; He, Lin (2007). "Mass Spectrometry Imaging of Small Molecules Using Desorption/Ionization on Silicon". Analytical Chemistry 79 (10): 3535–3541. doi:10.1021/ac0611465. ISSN 0003-2700.
|