InterCity 250

InterCity 250

Artist's impression of a Class 93 locomotive
Type and origin
Power type Electric
Builder Siemens, GEC-Alsthom or ABB Traction
Build date 1992—1995 (Proposed but never built)
Total produced 30 nine-carriage units
Specifications
UIC class Bo′Bo′+2′2′+...+2′2′+2′2′
Performance figures
Maximum speed 155 mph (250 km/h) (Design)
125 mph (200 km/h) (Initial Service)
Power output 7,400 horsepower (5.5 MW)
Career
Operators British Rail
Disposition Project cancelled in July 1992

InterCity 250 was the name of a proposed rolling stock, track and signalling upgrade project on the West Coast Main Line by British Rail in the early 1990s. The InterCity 250 train would have consisted of a Class 93 electric locomotive, nine Mark 5 coaches and a Mark 5 Driving Van Trailer operating in a push-pull formation. The project was cancelled by British Rail in July 1992 before production could begin.[1]

History

In 1985, work began to fully electrify the East Coast Main Line. This project, which saw the line fitted with overhead wires between London Kings Cross and Edinburgh, took five years to complete. At the same time, a new generation of rolling stock was introduced, with the Class 91 electric locomotives combined with the Mark 4 coaching stock to form what was termed the InterCity 225 train system - so called because the Class 91 locomotives had a top speed of 225 km/h (140  mph).

Upon the completion of the ECML project, British Rail turned to the West Coast Main Line. This had been electrified in several stages over a fifteen-year period between 1959 and 1974. However, unlike the ECML the extensive curvature of the track along the route meant that it was ill suited to running high-speed trains (generally defined in Britain as trains capable of 125 miles per hour (200 km/h) or more), and so its services were limited to more modest speeds of 100 to 110 miles per hour (161 to 177 km/h). In order to achieve the same standards as the ECML, major upgrade work of the track, signalling, OLE and a new generation of rolling stock were required.

During the late 1970s, British Rail had planned to address the WCML limitations with the Advanced Passenger Train project; this circumvented any requirement to make significant infrastructure changes by using tilting train technology. The project reached the prototype stage, with the introduction of three Class 370 electric multiple units into passenger service in 1981. However, initial failures of the tilt technology led to them being withdrawn. They were then used from 1984 to 1986 as test trains for researching the technologies and specifications required for what would become the Class 91.

Project scope

In November 1990, after several years of internal evaluation and development of business and technical specifications, British Rail announced the InterCity 250 project. This would address the problems on the WCML through the delivery of new rolling stock and enhanced infrastructure required to operate them. The proposal came at a time when journey time improvements on the West Coast Main Line were needed to increase revenue and improve InterCity's profitability. However the West Coast Main Line infrastructure at the time was incapable of supporting operation of 155 miles per hour (250 km/h) trains in normal service and in need of widespread renewal, therefore a number of factors would be required to deliver this:

Concept models for the Class 93 locomotives for the InterCity 250 were styled by Seymour Powell[3] and invitations to build the rolling stock were placed on 11 March 1991 with three manufacturers which included GEC-Alsthom Transportation, and joint bids from both Siemens (locomotives) and Bombardier Prorail (coaching stock), and ABB-BREL,[4] tendering to provide vehicles with an in-service date of 1995.

Consequently, the new InterCity 250 trains would have commenced operating at 125 miles per hour (200 km/h) around 1995, with incremental increases up to the maximum speed by the end of the 1990s following the implementation of in-cab signalling.[5] The East Coast Main Line high speed test site between Stoke Tunnel and New England North, used in the trial runs of the InterCity 225, was likely to have been used in the development and testing of a prototype InterCity 250 set.[6][7] In 1993 it was suggested that the InterCity 250 could provide a suitable specification for future replacement rolling stock on both the Great Western and East Coast Main Lines.[8]

In total the project was valued at around £750 million, with each IC250 formation estimated to cost £10 million (1992 prices).[9][10]

Cancellation

Due to the impact of the 1990s recession rolling stock orders placed by other sectors of British Rail led to a shortage of funding which saw many projects suspended or scrapped. Together with the impending privatisation of British Rail this led to the InterCity 250 project being abandoned in July 1992.

A later proposal in 1993 for the procurement of a follow-on set of ten InterCity 225 units for priority express operations on the WCML was not pursued on the basis that it was unable to deliver a commercially viable return on investment[2] and exposed the suppliers (GEC Transportation) to excessive financial risk. Existing operations by Class 86/87/90 and Mk2/3 stock would have been cascaded onto non-express services and branded "InterCity 175". The bid by BR was also hampered by a lack of available manufacturers, as Metro-Cammell and BREL were by that time heavily committed to production of the Class 365/465/466 Networker units.

Rolling stock

Legacy

The modernised West Coast Main Line now uses ‘Pendolino’ stock
Cab mockup

Although InterCity 250 was cancelled, the improvements to the WCML were still required and were campaigned for by the West Coast Rail 250 pressure group. Following the privatisation of British Rail in 1994, the newly formed rail infrastructure company Railtrack drew up plans for track and signalling upgrades to allow for high-speed running, which it budgeted at £2 billion. The predicted journey times for upgraded speeds of 125 mph (201 km/h) and 140 mph (225 km/h) over the existing 110 mph (177 km/h) maximum linespeed were based upon the calculated InterCity 250 performance over the West Coast Main Line supplied by British Rail (Derby).[11]

The first phase of the upgrade, between London Euston and Manchester was completed in 2004; however, work at several sites including Rugby and Milton Keynes stations, the Trent Valley and the remainder of the route to Glasgow continued until December 2008. The major inter-city passenger operator on the WCML, Virgin Trains, placed a rolling stock order worth £1 billion for 53 nine car sets of the new Class 390 Pendolino electric multiple unit. These are seen as the successor to the original APT concept, in that they utilise tilting technology to successfully negotiate the route of the WCML at high speed. Though infrastructure limitations presently limit them to 125 mph (201 km/h), the trains are capable of speeds up to 140 mph (225 km/h).

A full-size mock-up of the front end and cab of a class 93 power car was made. It is now at the Midland Railway Centre.[12]

See also

References

  1. "Facts and Figures - West Coast". Virgin Trains. Retrieved 2007-09-18.
  2. 1 2 "InterCity Story 1964-2012", C Green and M Vincent, Oxford Publishing Company, ISBN 978-0860936527, 2013.
  3. Designers Journal, Number 67, May 1991.
  4. Railway Magazine, Volume 147, 2001.
  5. "British Rail 1974-1997 - From Integration to Privatisation", T R Gourvish and M Anson, Oxford University Press, 2004.
  6. "Electrification of the East Coast Main Line - Project Completion Certificate" (PDF). British Rail. Retrieved 2009-07-09.
  7. "The Mk 4 and Mk 5 coaches for British Rail Intercity Part 2 : testing, commissioning and service experience with the Mk 4 coach and development of the Mk 5 specification", J A Higton and D R Temple, Proceedings of the Institute of Mechanical Engineers, Volume 206, 1992.
  8. "Modern Railway Transportation", J Ellis and C Green, Institution of Civil Engineers, 1993.
  9. "House of Commons Hansard Debates for 17 May 1995". Hansard. Retrieved 2008-11-30.
  10. "Passenger Transport After 2000 AD", G B R Feilden, A H Wickens and I R Yates, The Royal Society, E & F N Spon, ISBN 0-419-19470-3, 1992.
  11. "West Coast Main Line Modernisation - Feasibilty Study Report", WCML Development Company Ltd, 1994.
  12. https://www.flickr.com/photos/robert55012/6176569982/

External links

This article is issued from Wikipedia - version of the Saturday, April 02, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.