Olive oil acidity

Free acidity is an important parameter that defines the quality of olive oil and is defined as a percentage as grams of free fatty acids (expressed as oleic acid, the main fatty acid present in olive oil) in 100 grams of oil. As defined by the European Commission regulation No. 2568/91 and subsequent amendments,[1] the highest quality olive oil (Extra-Virgin olive oil) must feature a free acidity lower than 0.8%. Virgin olive oil is characterized by acidity between 0.8% and 2%, while lampante olive oil (a low quality oil that is not edible) features a free acidity higher than 2%.[2] The increase of free acidity in olive oil is due to free fatty acids that are released from triglycerides.

Mechanisms of free fatty acids formation

The presence of free fatty acids in olive oil is caused by a reaction (lipolysis) started when lipolytic enzymes (that are normally present in the pulp and seed cells of the olive) come in contact with the oil (that is contained in particular vacuoles) due to loss of integrity of the olive.[3] High values of free acidity in olive oil can be due different factors such as: production from unhealthy olives (due to microorganisms and moulds contamination or attacked by flies and parasites), bruised olives, delayed harvesting and storage before processing. The lipolysis reaction is greatly enhanced by the presence of an aqueous phase, so when oil is separated from water during processing, lipolysis slows down and stops.

Methods to measure olive oil free acidity

Free acidity is a defect of olive oil that is tasteless and odorless, thus can not be detected by sensory analysis. Since vegetable oils are not aqueous fluids, a pH-meter can not be used for this measure. Various approaches exist that can measure oil acidity with good accuracy.

Manual titration

The official technique to measure free acidity in olive oil (as defined by the European Commission regulation No. 2568/91) is a manual titration procedure: a known volume of the oil to be tested is added to a mix of ether, methanol and phenolphthalein, known volumes of potassium hydroxide KOH 0.1M (the titrant) are added until there is a change in the color of the solution. The total volume of added titrant is then used to estimate the free acidity. The official technique for acidity measure in olive oil is accurate and reliable, but is essentially a laboratory method that must be carried out by trained personnel (mainly because of the toxic compounds used). Hence is not suitable for in-situ measurements in small oil mills.

Near Infrared Spectroscopy

One of the most promising method is based on optical Near-infrared spectroscopy (NIR) where the optical absorbance, i.e. the fraction of intensity of the incident light that is absorbed by the oil sample, is used to estimate the oil acidity. An oil sample is placed in a cuvette and analyzed by a spectrophotometer on a wide range of wavelengths. The results (i.e. the absorbance data for every tested wavelength) are thus processed by a statistical algorithm, such as Principal Component Analysis (PCA) or Partial Least Squares regression (PLS), to estimate the oil acidity. The feasibility to measure olive oil free acidity and peroxide value by NIR spectroscopy in the wavenumber range 4541 to 11726 cm-1 was reported.[4] Many commercial spectrophotometers exist [5] that can be used for analysis of different quality parameters in olive oil. The main advantage of NIR spectroscopy is the possibility to carry out the analysis on raw olive oil samples, without any chemical pretreatment. The main drawbacks are the high cost of commercial spectrophotometer and the need of calibration for different types of oil (produced by olives of different varieties, different geographical origin, etc.).

Electrochemical Impedance Spectroscopy

Another approach is based on Electrochemical Impedance Spectroscopy (EIS). EIS is a powerful technique that has been widely used to characterize different food products such as the analysis of milk composition,[6] the characterization[7] and the determination of the freezing end-point[8] of ice-cream mixes, the measure of meat ageing,[9] the investigation of ripeness and quality in fruits.[10][11] Olive oil free acidity determination using EIS is quick and simple: the olive oil sample is mixed with an hydro-alcoholic solution (60% ethanol, 40% distilled water) to create an emulsion and the emulsion electrical conductance is measured. The measured value is then used to estimate the free acidity.[12] The main advantage of this technique is that is rapid, the reagents used are non toxic and can be easily implemented in the form of a portable electronic system for in-situ measurements in olive oil mills.

References

  1. "Regulation (EEC) No 2568/91 on the characteristics of olive oil and olive-residue oil and on the relevant methods of analysis".
  2. Grossi, M.; Di Lecce, G.; Gallina Toschi, T.; Riccò, B. (2014). "Fast and accurate determination of olive oil acidity by electrochemical impedance spectroscopy". IEEE Sensors Journal 14 (9): 2947–2954. doi:10.1109/JSEN.2014.2321323.
  3. Peri, Claudio (2014). The Extra-Virgin Olive Oil Handbook. Wiley-Blackwell. ISBN 978-1-118-46045-0.
  4. Armenta, S.; Garrigues, S.; De la Guardia, M. (2007). "Determination of edible oil parameters by near infrared spectrometry". Analytica Chimica Acta 596 (2): 330–337. doi:10.1016/j.aca.2007.06.028.
  5. "NIR Olive Analyzer T-38 Mini".
  6. Mabrook, M.F.; Petty, M.C. (2003). "Effect of composition on the electrical conductance of milk". Journal of Food Engineering 60 (3): 321–325. doi:10.1016/S0260-8774(03)00054-2.
  7. Grossi, M.; Lanzoni, M.; Lazzarini, R.; Riccò, B. (2012). "Automatici ce-cream characterization by impedance measurements for optimal machine setting". Measurement 45: 1747–1754. doi:10.1016/j.measurement.2012.04.009.
  8. Grossi, M.; Lazzarini, R.; Lanzoni, M.; Riccò, B. (2011). "A novel technique to control ice-cream freezing by electrical characteristics analysis". Journal of Food Engineering 106: 347–354. doi:10.1016/j.jfoodeng.2011.05.035.
  9. Damez, J.L.; Clerion, S.; Abouelkaram, S.; Lepetit, J. (2008). "Beef meat electrical impedance spectroscopy and anisotropy sensing for non-invasive early assessment of meat ageing". Journal of Food Engineering 85 (1): 116–122. doi:10.1016/j.jfoodeng.2007.07.026.
  10. Rehman, M.; Abu Izneid, J.A.; Abdullha, M.Z.; Arshad, M.R. (2011). "Assessment of quality of fruits using impedance spectroscopy". International Journal of Food Science & Technology 46 (6): 1303–1309. doi:10.1111/j.1365-2621.2011.02636.x.
  11. Harker, F.R.; Forbes, S.K. (1997). "Ripening and development of chilling injury in persimmon fruit: An electrical impedance study". New Zealand Journal of Crop and Horticultural Science 25 (2): 149–157. doi:10.1080/01140671.1997.9514001.
  12. Grossi, M.; Di Lecce, G.; Gallina Toschi, T.; Riccò, B. (2014). "A novel electrochemical method for olive oil acidity determination". Microelectronics Journal 45: 1701–1707. doi:10.1016/j.mejo.2014.07.006.
This article is issued from Wikipedia - version of the Friday, March 11, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.