Thin layer extraction

Thin layer extraction is a time-periodic reactive liquid extraction process that provides excellent mass transfer while maintaining phase separation.[1] It is performed via a periodic batch production process the controls the time of each chemical reaction..

Approach

A small amount of a liquid organic extract is spread, as a thin layer, onto a matrix made of a thin microporous material whose surfaces are freely accessible from and to the outside. The extract is held by capillary forces or other forces. This layer is alternately and repeatedly brought into brief contact with thin layers of the donor and the strip aqueous liquid. In the extraction step, selected species that are present in the donor solution are transported from the donor aqueous solution to the organic phase where a reaction ensues. In the stripping step the reaction reverses and the extracted species are stripped into the strip aqueous solution. Thus, two alternate product batches are generated: a raffinate and a strip product. As each of the species to be separated associates differently with the host, the composition of the raffinate and strip product is differentiated.

Unique characteristics

WITH a typical liquid mass diffusivity in the order of 10−9 m2/s,[2] the characteristic time for diffusion through a 20 micron thick liquid layer is 0.4 s. Therefore, the thinness of both phases (organic and aqueous) causes a relatively "immediate" mass transfer of guest species from one phase to the other, which means that this process has a low mass transfer resistance. The low mass transfer resistance permits the uncoupling of effects attributed to mass transfer from the effects attributed to the reaction rates; it also allows a relatively frequent cycling that helps mitigate the limited capacity that is due to the small batches of aqueous feed processed within each cycle.

Application to kinetic reactive thin layer extraction

A second characteristic of thin layer extraction arises from the batch periodic mode of operation. It permits precise control in time and space over small processed elements in the course of the process, a degree of control that is not possible in any other liquid-liquid extraction method. This control is instrumental in enabling the exploitation of differences in reaction rates of the different species (see Thermodynamic versus kinetic reaction control) and the “harvesting” of separated species early on the reaction trajectories where the relative differences in concentration are largest. This forms the basis for kinetic, reactive, thin layer extraction.[3]

Process conditions

The extractant, including the host, must be substantially insoluble in the processed aqueous solutions to avoid being washed away. However, the difference in density between the immiscible phases, which plays an important role in conventional liquid-liquid extraction, is irrelevant in thin layer extraction.

Potential applications

When the separation of two closely related compounds by liquid–liquid extraction is necessary, conventional wisdom indicates that a selective extractant must be found that will discern between the two by associating each to different equilibrium compositions.

Thin layer extraction is recommended for the separation of high-value products that are produced in moderate volumes (for example the separation of chiral molecules[4][5]).

Equipment

Thin layer extraction is used in specialized equipment operated as robots consisting of:

A thin layer extraction cell consists of a section of the matrix that takes turn at being alternately exposed to the donor and then the strip solutions. Each cell accepts two alternating aqueous feed batches and generates two corresponding alternating batches of the products.

In multistage operation, a train of cells is operated synchronously with the products from one cell directed as feeds to a next upstream or downstream cell.

Multistage thin layer extraction scheme

The multistage thin layer extraction equipment is linearly scalable, permitting results obtained on table-top laboratory devices to be directly scaled up to full-scale production plants.

References

  1. Lavie R., “Thin Layer Extraction – A Novel Liquid-Liquid Extraction Method”, AIChE Journal, 54, Issue 4, Pages 957-964, 2008. DOI: 10.1002/aic.11445.
  2. Ven_Lucassen, I., “ Diffusion coefficients in liquid systems”, Thesis – Technische University Eindhoven, 1999, ISBN 90-3862551-0.
  3. Ram Lavie, "Kinetic Reactive Thin Layer Extraction",Industrial & Engineering Chemistry Research, Volume 53, Issue 47, pages 18283–18290, DOI: 10.1021/ie5026387.
  4. Lavie R. and Wajc S., “Chiral Resolution by Thin Layer Extraction”, Chemical Engineering Transactions, Volume 24, pages 739-744, 2011, DOI: 10.3303/CET1124124.
  5. Lavie R., "Chiral Resolution of Ionic Compounds by Thin Layer Extraction", Ind. & Eng. Chemistry Research,2011, Vol. 50, Issue 22, pages 12311-12844, DOI: 10.1021/ie201596n.
This article is issued from Wikipedia - version of the Friday, April 01, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.