Tomotherapy

Tomotherapy Hi Art

Tomotherapy is a type of radiation therapy in which the radiation is delivered slice-by-slice (hence the use of the Greek prefix tomo-, which means "slice"). This method of delivery differs from older techniques where one or more opposing fields of radiation would encompass the entire tumor but result in significantly more radiation to normal structures.

History

The first implementation of tomotherapy was the Corvus system developed by Nomos Corporation, with the first patient treated in April, 1994.[1] This was the first commercial system for planning and delivering intensity modulated radiation therapy (IMRT). The original system, designed solely for use in the brain, incorporated a rigid skull-based fixation system to prevent patient motion between the delivery of each slice of radiation. But some users eschewed the fixation system and applied the technique to tumors in many different parts of the body.

Tomotherapy, or Helical Tomotherapy, is a form of computed tomography (CT) guided IMRT or Intensity Modulated Radiation Therapy, which is a relatively new type of radiation therapy delivery system. The system was developed at the University of Wisconsin–Madison by professor Thomas Rockwell Mackie, Ph.D. and Paul Reckwerdt. A small megavoltage x-ray source was mounted in a similar fashion to a CT x-ray source, and the geometry provided the opportunity to provide CT images of the body in the treatment setup position. Although original plans were to include kilovoltage CT imaging, current models use megavoltage energies. With this combination, the unit was one of the first devices capable of providing modern image-guided radiation therapy (IGRT). The first patients were treated in 2002, at the University of Wisconsin under the guidance of Professor Minesh Mehta, M.D., under the auspices of an NIH-funded Program Project Grant.

General Principles

In general, radiation therapy (or radiotherapy) has developed with a strong reliance on homogeneity of dose throughout the tumor. Tomotherapy embodies the sequential delivery of radiation to different parts of the tumor which raises two important issues. First, this method is known as "field matching" and brings with it the possibility of a less-than-perfect match between two adjacent fields with a resultant hot and/or cold spot within the tumor. The second issue is that if the patient or tumor moves during this sequential delivery, then again, a hot or cold spot will result. The first problem can be overcome, or at least minimized, by careful construction of the beam delivery system. The second requires close attention to the position of the target throughout treatment delivery. All this can be done with during the radiation planning process which makes tomotherapy the most homogeneous radiation treatment delivery machine.


At this time, the Hi-Art system manufactured by TomoTherapy Inc. is the primary tomotherapy device in use although there are still a number of Corvus systems being used. TomoTherapy TomoHD systems are also in use. Other radiation therapy equipment vendors have recently responded to the challenge of short treatment times coupled with a full 360-degree treatment arc by developing methods of delivering IMRT using arcs. The major difference is that these methods are implemented on standard medical linear accelerators, thereby providing for complete volumetric irradiation.

Patient undergoing tomotherapy, face and body covered.

TomoTherapy "beam on" times are comparable to normal radiation therapy treatment times (about 35 minutes beam on time for a common prostate treatment) but do add an additional 23 minutes for a daily CT. The daily CT is used to precisely place the radiation beam and allows the operator to modify the treatment should the patients anatomy change due to weight loss or tumor shrinkage (adaptive radiotherapy). Lung cancer, head and neck tumors, breast cancer, prostate cancer, stereotactic radiosurgery(SRS) and stereotactic body radiotherapy (SBRT) are some examples of treatments commonly performed using TomoTherapy. A number of product upgrades have been developed over the past decade leading to decreased treatment times, increased machine reliability and improved dose distributions. Numerous peer reviewed articles have demonstrated more conformal treatment plans and decreased acute toxicity. While the first clinical use of TomoTherapy was in 2002, at the University of Wisconsin, under the leadership of Dr. Minesh Mehta, M.D., there are now more than 500 sites across Canada, the United States, Europe and Asia. The Cromwell Hospital in London was the first UK site to offer Tomotherapy under the leadership of Prof Christopher Nutting.

Due to their internal shielding and small footprint, TomoTherapy Hi-Art and TomoTherapy TomoHD treatment machines are the only high energy radiotherapy treatment machines used in relocatable radiotherapy treatment suites. Two different types of suites are available: TomoMobile developed by TomoTherapy Inc. which is a moveable truck and Pioneer, developed by UK-based Oncology Systems Limited. The latter was developed to meet the requirements of UK and European transport law requirements and is a contained unit that is placed on a concrete pad, delivering radiotherapy treatments in less than five weeks.

See also


Notes

  1. "SU-FF-T-457: Whole-Body Dose for Helical Tomotherapy". Medical Physics. Retrieved 2009-05-19.