Nuclear reactor accidents in the United States

Erosion of the 6-inch-thick (150 mm) carbon steel reactor head, caused by a persistent leak of borated water, at the Davis-Besse Nuclear Power Plant.

The United States Government Accountability Office reported more than 150 incidents from 2001 to 2006 of nuclear plants not performing within acceptable safety guidelines. According to a 2010 survey of energy accidents, there have been at least 56 accidents at nuclear reactors in the United States (defined as incidents that either resulted in the loss of human life or more than US$50,000 of property damage). The most serious of these was the Three Mile Island accident in 1979. Davis-Besse Nuclear Power Plant has been the source of two of the top five most dangerous nuclear incidents in the United States since 1979.[1] Relatively few accidents have involved fatalities.[2]

Context

Globally, there have been at least 99 (civilian and military) recorded nuclear reactor accidents from 1952 to 2009 (defined as incidents that either resulted in the loss of human life or more than US$50,000 of property damage, the amount the US federal government uses to define major energy accidents that must be reported), totaling US$20.5 billion in property damages. The accidents involved meltdowns, explosions, fires, and loss of coolant, and occurred during both normal operation and extreme emergency conditions (such as droughts and earthquakes). Property damage costs include destruction of property, emergency response, environmental remediation, evacuation, lost product, fines, and court claims.[2] Because nuclear reactors are large and complex accidents onsite tend to be relatively expensive.[3]

At least 56 nuclear reactor accidents have occurred in the USA. Relatively few accidents have involved fatalities.[2] The most serious of these U.S. accidents was the Three Mile Island accident in 1979. According to the Nuclear Regulatory Commission, the Davis–Besse Nuclear Power Station has been the source of two of the top five most dangerous nuclear incidents in the United States since 1979.[1]

The United States Government Accountability Office reported more than 150 incidents from 2001 to 2006 alone of nuclear plants not performing within acceptable safety guidelines. In 2006, it said: "Since 2001, the ROP has resulted in more than 4,000 inspection findings concerning nuclear power plant licensees’ failure to fully comply with NRC regulations and industry standards for safe plant operation, and NRC has subjected more than 75 percent (79) of the 103 operating plants to increased oversight for varying periods".[4]

History

The Atomic Energy Act of 1954 encouraged private corporations in the United States to build nuclear reactors and a significant learning phase followed with many early partial core meltdowns and accidents at experimental reactors and research facilities.[5] This led to the introduction of the Price-Anderson Act in 1957, which was "an implicit admission that nuclear power provided risks that producers were unwilling to assume without federal backing".[5]

Nuclear reactor accidents continued into the 1960s with a small test reactor exploding at the Stationary Low-Power Reactor Number One in Idaho Falls in January 1961 resulting in three deaths which were the first fatalities in the history of U.S. nuclear reactor operations.[6] There was also a partial meltdown at the Enrico Fermi Nuclear Generating Station in Michigan in 1966.[5]

The large size of nuclear reactors ordered during the late 1960s raised new safety questions and created fears of a severe reactor accident that would send large quantities of radiation into the environment. In the early 1970s, a highly contentious debate over the performance of emergency core cooling systems in nuclear plants, designed to prevent a core meltdown that could lead to the "China syndrome", received coverage in the popular media and technical journals.[7][8]

In 1976, four nuclear engineersthree from GE and one from the Nuclear Regulatory Commission— resigned, stating that nuclear power was not as safe as their superiors were claiming.[9][10][11][12] They testified to the Joint Committee on Atomic Energy that:

"the cumulative effect of all design defects and deficiencies in the design, construction and operations of nuclear power plants makes a nuclear power plant accident, in our opinion, a certain event. The only question is when, and where.[9]

Three Mile Island accident

President Jimmy Carter leaving Three Mile Island for Middletown, Pennsylvania, April 1, 1979

On March 28, 1979, equipment failures and operator error contributed to loss of coolant and a partial core meltdown of Unit 2's pressurized water reactor at the Three Mile Island Nuclear Power Plant in Pennsylvania.[13] The scope and complexity of this reactor accident became clear over the course of five days, as a number of agencies at the local, state and federal levels tried to solve the problem and decide whether the ongoing accident required an emergency evacuation, and to what extent.

Cleanup started in August 1979 and officially ended in December 1993, with a total cleanup cost of about $1 billion.[14] Benjamin K. Sovacool, in his 2007 preliminary assessment of major energy accidents, estimated that the TMI accident caused a total of $2.4 billion in property damages.[15] The health effects of the Three Mile Island accident are widely, but not universally, agreed to be very low level.[16][17]

The TMI accident forced regulatory and operational improvements on a reluctant industry, but it also increased opposition to nuclear power.[18] The accident triggered protests around the world.[19]

List of accidents and incidents

Nuclear reactor accidents in the U.S.[3][20]
Date Location Description Fatalities Cost
(in millions
2006 US$)
INES
rating
November 29, 1955 Idaho Falls, Idaho, US Power excursion with partial core meltdown at National Reactor Testing Station's EBR-1 Experimental Breeder Reactor I 0 5
July 26, 1959 Simi Valley, California, USA Partial core meltdown at Santa Susana Field Laboratory’s Sodium Reactor Experiment 0 32
January 3, 1961 Idaho Falls, Idaho, US Explosion with three fatalities at National Reactor Testing Station's SL-1 Stationary Low-Power Reactor Number One 3 22
July 24, 1964 Charlestown, Rhode Island, United States An error by a worker at a United Nuclear Corporation fuel facility led to an accidental criticality 1 ??
October 5, 1966 Monroe, Michigan, USA Sodium cooling system malfunctions at Enrico Fermi demonstration breeder reactor causing partial core meltdown 0 19
July 16, 1971 Cordova, Illinois, USA An electrician is electrocuted by a live cable at the Quad Cities Unit 1 reactor on the Mississippi River 1 1
August 11, 1973 Covert Township, Michigan, USA Steam generator leak at the Palisades Nuclear Generating Station causes manual shutdown of pressurized water reactor 0 10
March 22, 1975 Athens, Alabama, USA Fire burns for seven hours and damages more than 1600 control cables for three nuclear reactors at Browns Ferry, disabling core cooling systems 0 240
November 5, 1975 Brownville, Nebraska, USA Hydrogen gas explosion damages the Cooper Nuclear Facility’s Boiling Water Reactor and an auxiliary building 0 13
June 10, 1977 Waterford, Connecticut, USA Hydrogen gas explosion damages three buildings and forces shutdown of Millstone-1 Boiling Water Reactor 0 15
February 4, 1979 Surry, Virginia, USA Surry Unit 2 shut down in response to failing tube bundles in steam generators 0 12
March 28, 1979 Middletown, Pennsylvania, US Loss of coolant and partial core meltdown, see Three Mile Island accident and Three Mile Island accident health effects 0 2,400 5[21]
November 22, 1980 San Clemente, California, USA Worker cleaning breaker cubicles at San Onofre Pressurized Water Reactor contacts an energized line and is electrocuted 1 1
January 25, 1982 Ontario, New York, USA Ginna Nuclear Generating Station (then operated by Rochester Gas & Electric now by Constellation Energy Nuclear Group) experiences a steam tube rupture, releasing radioactivity into the environment. 0 1
February 26, 1982 San Clemente, California, USA Southern California Company shuts down San Onofre Unit 1 out of concerns about earthquake 0 1
March 20, 1982 Scriba, New York, USA Recirculation system piping fails at Nine Mile Point Unit 1, forcing two year shutdown 0 45
March 25, 1982 Buchanan, New York, USA Damage to steam generator tubes and main generator resulting in a shut down Indian Point Energy Center Unit 3 for more than a year 0 56
June 18, 1982 Seneca, South Carolina, USA Feedwater heat extraction line fails at Oconee 2 Pressurised Water Reactor, damaging thermal cooling system 0 10
February 12, 1983 Forked River, New Jersey, USA Oyster Creek Nuclear Generating Station fails safety inspection, forced to shut down for repairs 0 32
February 26, 1983 Fort Pierce, Florida, USA Damaged thermal shield and core barrel support at St. Lucie Unit 1, necessitating 13-month shutdown 0 54
September 15, 1984 Athens, Alabama, US Safety violations, operator error, and design problems force six year outage at Browns Ferry Unit 2 0 110
March 9, 1985 Athens, Alabama, US Instrumentation systems malfunction during start-up, which led to suspension of operations at all three Browns Ferry Units 0 1,830
June 9, 1985 Oak Harbor, Ohio, US Loss of feedwater event at Davis-Besse reactor after main pumps shut down and auxiliary pumps tripped due to operator error. NRC review determines site area emergency should have been declared 0 ?
April 11, 1986 Plymouth, Massachusetts, US Recurring equipment problems force emergency shutdown of Boston Edison’s Pilgrim Nuclear Power Plant 0 1,001
March 31, 1987 Delta, Pennsylvania, US Peach Bottom units 2 and 3 shutdown due to cooling malfunctions and unexplained equipment problems 0 400
July 15, 1987 Burlington, Kansas, USA Safety inspector dies from electrocution after contacting a mislabeled wire at Wolf Creek Nuclear Generating Station 1 1
December 19, 1987 Scriba, New York, US Malfunctions force Niagara Mohawk Power Corporation to shut down Nine Mile Point Unit 1 0 150
March 29, 1988 Burlington, Kansas, USA A worker at the Wolf Creek Generating Station falls through an unmarked manhole and electrocutes himself when trying to escape 1 1
September 10, 1988 Surry, Virginia, USA Refuelling cavity seal fails and destroys internal pipe system at Surry Unit 2, forcing 12-month outage 0 9
March 5, 1989 Tonopah, Arizona, USA Atmospheric dump valves fail at Palo Verde Unit 1, leading to main transformer fire and emergency shutdown 0 14
March 17, 1989 Lusby, Maryland, US Inspections at Calvert Cliff Units 1 and 2 reveal cracks at pressurized heater sleeves, forcing extended shutdowns 0 120
November 17, 1991 Scriba, New York, USA Safety and fire problems force shut down of the FitzPatrick nuclear reactor for 13 months 0 5
April 21, 1992 Southport, North Carolina, USA NRC forces shut down of Brunswick Units 1 and 2 after emergency diesel generators fail 0 2
February 3, 1993 Bay City, Texas, USA Auxiliary feed-water pumps fail at South Texas Project Units 1 and 2, prompting rapid shutdown of both reactors 0 3
February 27, 1993 Buchanan, New York, USA New York Power Authority shuts down Indian Point Energy Center Unit 3 after AMSAC system fails 0 2
March 2, 1993 Soddy-Daisy, Tennessee, USA Equipment failures and broken pipes cause shut down of Sequoyah Unit 1 0 3
December 25, 1993 Newport, Michigan, USA Shut down of Fermi Unit 2 after main turbine experienced major failure due to improper maintenance 0 67
14 January 1995 Wiscasset, Maine, USA Steam generator tubes unexpectedly crack at Maine Yankee nuclear reactor; shut down of the facility for a year 0 62
May 16, 1995 Salem, New Jersey, USA Ventilation systems fail at Salem Units 1 and 2 0 34
February 20, 1996 Waterford, Connecticut, US Leaking valve forces shutdown Millstone Nuclear Power Plant Units 1 and 2, multiple equipment failures found 0 ?
May 15, 1996 Morris, Illinois, US Plunging water levels around the nuclear fuel in the reactor's core prompt shut down at Dresden Generating Station 0 ?
September 2, 1996 Crystal River, Florida, US Balance-of-plant equipment malfunction forces shutdown and extensive repairs at Crystal River Unit 3 0 384
September 5, 1996 Clinton, Illinois, USA Reactor recirculation pump fails, prompting shut down of Clinton boiling water reactor 0 38
September 20, 1996 Seneca, Illinois, USA Service water system fails and results in closure of LaSalle Units 1 and 2 for more than 2 years 0 71
September 9, 1997 Bridgman, Michigan, USA Ice condenser containment systems fail at Cook Units 1 and 2 0 11
May 25, 1999 Waterford, Connecticut, USA Steam leak in feed-water heater causes manual shutdown and damage to control board annunicator at the Millstone Nuclear Power Plant 0 7
September 29, 1999 Lower Alloways Creek Township, New Jersey, USA Major Freon leak at Hope Creek Nuclear Generating Station causes ventilation train chiller to trip, releasing toxic gas and damaging the cooling system 0 2
February 15, 2000 Buchanan, New York, USA NRC Alert issued after steam tube rupture Indian Point Unit 2 [22] 0 2
February 16, 2002 Oak Harbor, Ohio, US Severe boric acid corrosion of reactor head forces 24-month outage of Davis-Besse reactor 0 605[23]
January 15, 2003 Bridgman, Michigan, USA A fault in the main transformer at the Donald C. Cook Nuclear Generating Station causes a fire that damages the main generator and back-up turbines 0 10
June 16, 2005 Braidwood, Illinois, USA Exelon’s Braidwood nuclear station leaks tritium and contaminates local water supplies 0 41
August 4, 2005 Buchanan, New York, USA Entergy’s Indian Point Nuclear Plant leaks tritium and strontium into underground lakes from 1974 to 2005 30
March 6, 2006 Erwin, Tennessee, USA Nuclear Fuel Services plant spills 35 litres of highly enriched uranium, necessitating 7-month shutdown 0 98
September 2009 Crystal River, Florida, USA When cutting into Crystal River 3 Nuclear Power Plant containment building to create a large opening for the replacement of the Steam generator (nuclear power) the structure was severely cracked resulting in the permanent closure of the facility. 0 1,000+
February 1, 2010 Vernon, Vermont, US Deteriorating underground pipes from the Vermont Yankee Nuclear Power Plant leak radioactive tritium into groundwater supplies 0 700
July 15, 2011 Morris, Illinois, US Chemical leak of sodium hypochlorite restricted access to a vital area that houses plant cooling water pumps at Dresden Generating Station 0 ?
January 30, 2012 Byron, Illinois, US Unusual Incident reported at Byron Nuclear Generating Station. Loss of off-site power caused unit 2 to run a shut down cycle and release tritium steam into the atmosphere 0 Undetermined
March 31, 2013 Russellville, Arkansas, US One worker was killed and two others injured when part of a generator fell as it was being moved at the Arkansas Nuclear One. 1 ?
This list is incomplete; you can help by expanding it.

Nuclear safety

A clean-up crew working to remove radioactive contamination after the Three Mile Island accident.

Nuclear safety in the U.S. is governed by federal regulations issued by the Nuclear Regulatory Commission (NRC). The NRC regulates all nuclear plants and materials in the U.S. except for of nuclear plants and materials controlled by the U.S. government, as well those powering naval vessels.[24][25]

The 1979 Three Mile Island accident was a pivotal event that led to questions about U.S. nuclear safety.[26] Earlier events had a similar effect, including a 1975 fire at Browns Ferry, the 1976 testimonials of three concerned GE nuclear engineers, the GE Three. In 1981, workers inadvertently reversed pipe restraints at the Diablo Canyon Power Plant reactors, compromising seismic protection systems, which further undermined confidence in nuclear safety. All of these well-publicised events, undermined public support for the U.S. nuclear industry in the 1970s and the 1980s.[26]

Recent concerns have been expressed about safety issues affecting a large part of the nuclear fleet of reactors. In 2012, the Union of Concerned Scientists, which tracks ongoing safety issues at operating nuclear plants, found that "leakage of radioactive materials is a pervasive problem at almost 90 percent of all reactors, as are issues that pose a risk of nuclear accidents".[27]

Following the Japanese Fukushima Daiichi nuclear disaster, according to Black & Veatch’s annual utility survey that took place after the disaster, of the 700 executives from the US electric utility industry that were surveyed, nuclear safety was the top concern.[28] There are likely to be increased requirements for on-site spent fuel management and elevated design basis threats at nuclear power plants.[29][30] License extensions for existing reactors will face additional scrutiny, with outcomes depending on the degree to which plants can meet new requirements, and some of the extensions already granted for more than 60 of the 104 operating U.S. reactors could be revisited. On-site storage, consolidated long-term storage, and geological disposal of spent fuel is "likely to be reevaluated in a new light because of the Fukushima storage pool experience".[29]

In October 2011, the Nuclear Regulatory Commission instructed agency staff to move forward with seven of the 12 safety recommendations put forward by the federal task force in July. The recommendations include "new standards aimed at strengthening operators’ ability to deal with a complete loss of power, ensuring plants can withstand floods and earthquakes and improving emergency response capabilities". The new safety standards will take up to five years to fully implement.[31]

See also

References

  1. 1 2 Nuclear Regulatory Commission (2004-09-16). "Davis-Besse preliminary accident sequence precursor analysis" (PDF). Retrieved 2006-06-14. and Nuclear Regulatory Commission (2004-09-20). "NRC issues preliminary risk analysis of the combined safety issues at Davis-Besse". Retrieved 2006-06-14.
  2. 1 2 3 Benjamin K. Sovacool. A Critical Evaluation of Nuclear Power and Renewable Electricity in Asia, Journal of Contemporary Asia, Vol. 40, No. 3, August 2010, pp. 379-380.
  3. 1 2 Benjamin K. Sovacool (2009). The Accidental Century - Prominent Energy Accidents in the Last 100 Years
  4. United States Government Accountability Office (2006). "Report to Congress" (PDF). p. 4.
  5. 1 2 3 Benjamin K. Sovacool. The costs of failure: A preliminary assessment of major energy accidents, 1907–2007, Energy Policy 36 (2008), p. 1808.
  6. Perhaps the Worst, Not the First TIME magazine, May 12, 1986.
  7. Walker, J. Samuel (2004). Three Mile Island: A Nuclear Crisis in Historical Perspective (Berkeley: University of California Press), pp. 10-11.
  8. Wolfgang Rudig (1990). Anti-nuclear Movements: A World Survey of Opposition to Nuclear Energy, Longman, pp. 66-67.
  9. 1 2 Mark Hertsgaard (1983). Nuclear Inc. The Men and Money Behind Nuclear Energy, Pantheon Books, New York, p. 72.
  10. Jim Falk (1982). Global Fission: The Battle Over Nuclear Power, Oxford University Press, p. 95.
  11. The San Jose Three TIME, Feb. 16, 1976.
  12. The Struggle over Nuclear Power TIME, Mar. 08, 1976.
  13. World Nuclear Association (1999). Three Mile Island: 1979 Retrieved December 24, 2008.
  14. "14-Year Cleanup at Three Mile Island Concludes". New York Times. August 15, 1993. Retrieved March 28, 2011.
  15. Benjamin K. Sovacool. The costs of failure: A preliminary assessment of major energy accidents, 1907–2007, Energy Policy 36 (2008), p. 1807.
  16. Mangano, Joseph (2004). Three Mile Island: Health study meltdown, Bulletin of the atomic scientists, 60(5), pp. 31 -35.
  17. World Nuclear Association. Three Mile Island Accident January 2010.
  18. Wellock, Thomas R. Three Mile Island: A Nuclear Crisis in Historical Perspective (Book review) The Historian, 22 September 2005.
  19. Mark Hertsgaard (1983). Nuclear Inc. The Men and Money Behind Nuclear Energy, Pantheon Books, New York, p. 95 & 97.
  20. Benjamin K. Sovacool. A Critical Evaluation of Nuclear Power and Renewable Electricity in Asia, Journal of Contemporary Asia, Vol. 40, No. 3, August 2010, pp. 393–400.
  21. http://www.iaea.org/ns/tutorials/regcontrol/appendix/app96.htm
  22. Bel, Hubert T. l. "Inspector General Report - Ind" (PDF). Office of the Inspector General (OIG), U.S. Nuclear Regulatory Commission (NRC).
  23. Blade, Toledo. "Davis-Besse stirs again". Toledo Blade.
  24. About NRC, U.S. Nuclear Regulatory Commission. Retrieved 2007-6-1.
  25. Our Governing Legislation, U.S. Nuclear Regulatory Commission. Retrieved 2007-6-1.
  26. 1 2 Nathan Hultman and Jonathan Koomey (1 May 2013). "Three Mile Island: The driver of US nuclear power’s decline?". Bulletin of the Atomic Scientists.
  27. Mark Cooper (2012-68-61). "Nuclear safety and affordable reactors: Can we have both?" (PDF). Bulletin of the Atomic Scientists. Check date values in: |date= (help)
  28. Eric Wesoff, Greentechmedia. "Black & Veatch’s 2011 Electric Utility Survey." June 16, 2011. Retrieved October 11, 2011.
  29. 1 2 Massachusetts Institute of Technology (2011). "The Future of the Nuclear Fuel Cycle" (PDF). p. xv.
  30. Mark Cooper (July 2011). "The implications of Fukushima: The US perspective". Bulletin of the Atomic Scientists. p. 9.
  31. Andrew Restuccia (2011-10-20). "Nuke regulators toughen safety rules". The Hill.